Advertisement

Quick Links

Installation and Operating Manual
FREESTANDING FIREPLACE, AS A ZERO CLEARANCE FIREPLACE OR
WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
Do not store or use gasoline or other fl ammable vapors and liquids in vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow gas supplier's instructions
If you cannot reach your gas supplier, call fi re department.
Installation and service must be performed by a qualifi ed installer, service agency or gas supplier.
This is an unvented gas-fi red heater. It uses air (oxygen) from room in which it is installed. Provisions for
adequate combustion and ventilation air must be provided. Refer to section," Producing Adequate Air
For Combustion And Ventilation". This appliance may be installed in an aftermarket, permanently located,
manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with type
of gas indicated on rating plate. This appliance is not convertible for use with other gases.
INSTALLER: Leave this manual with appliance.
CONSUMER: Retain this manual for future reference.
This appliance is intended for supplemental heating.
AGVF340
MAY BE INSTALLED IN A SOLID FUEL BURNING FIREPLACE, AS A
WITH AN OPTIONAL WOODEN SURROUND
Certifi ed for installations in the USA
Approved for installation in mobile homes
This appliance may be installed in an aftermarket,
permanently located, manufactured (mobile) how,
where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases.
852372B-1904E

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AGVF340 and is the answer not in the manual?

Questions and answers

Summary of Contents for Ashley AGVF340

  • Page 1 Installation and Operating Manual AGVF340 MAY BE INSTALLED IN A SOLID FUEL BURNING FIREPLACE, AS A FREESTANDING FIREPLACE, AS A ZERO CLEARANCE FIREPLACE OR WITH AN OPTIONAL WOODEN SURROUND Certifi ed for installations in the USA Approved for installation in mobile homes WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
  • Page 2: Safety Information Warnings

    SECTION I IMPORTANT: READ THIS OWNER’S MANUAL CAREFULLY AND COMPLETELY BEFORE TRYING TO ASSEMBLE, OPERATE, OR SERVICE APPLIANCE. IMPROPER USE OF THESE LOGS CAN CAUSE SERIOUS INJURY OR DEATH FROM BURNS, FIRE, EXPLOSION AND CARBON MONOXIDE POISONING. IMPORTANT: VENT-FREE HEATERS ADD MOISTURE TO AIR. ALTHOUGH THIS IS BENEFICIAL, INSTALLING HEATER IN ROOMS WITHOUT ADEQUATE VENTILATION MAY CAUSE MILDEW TO FORM FROM TOO MUCH MOISTURE.
  • Page 3 7. “This heater shall not be installed in unusually tight 20. All heater screens must be kept closed when construction unless provisions are provided for operating gas logs. adequate combustion and ventilation air.” See “Producing Adequate Air For Combustion And 21.
  • Page 4 SECTION II SAFETY INFORMATION WARNINGS The fi replace needs to be prepared before installing heater. A. Turn off the gas supply to fi replace. “WARNING: BEFORE INSTALLING IN A SOLID-FUEL BURNING FIREPLACE, CHIMNEY FLUE AND FIREBOX MUST BE CLEANED OF SOOT, CREOSOTE, ASHES AND LOOSE PAINT BY A QUALIFIED CHIMNEY CLEANER.”...
  • Page 5: Gas Connection

    INSTALLATION AND CLEARANCES To ensure a safe installation into a masonry or factory built fi replace, following instructions must be carefully followed: 1. Sidewall Clearances: Clearance from side of fi replace opening to any adjacent combustible wall should not be less than: right side 7”, left side 7”.
  • Page 6 LOG SET PLACEMENT E.S.B. LOG SET PLACEMENT FOR MODEL 384 “MILLIVOLT ONLY” WARNING: FAILURE TO POSITION PARTS IN ACCORDANCE WITH THESE DIAGRAMS OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS HEATER MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY. WARNING: POSITIONING OF LOGS IS VERY CRITICAL (SEE DIAGRAM ABOVE) (1) Rear Log, (2) Middle Log, (3) Left Top Middle Log, (4) Right Top Middle Log (5), Left Front Log (6), Right Front Log (7), Glowing Embers in front of 5 &...
  • Page 7: Gas Pressure Check

    GAS PRESSURE CHECK Check inlet pressure to burner to ensure that it is as shown in table below. NOTE: The pressure check point is located on the right side of valve facing burner, for SIT Millivolt, and left side for SIT Modulating. Appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5kPa).
  • Page 8: What To Do If You Smell Gas

    OPERATING INSTRUCTIONS Before operating this appliance, proceed through following checklist. 1. Read and understand these instructions before operating this appliance. 2. Check that there are no gas leaks. If you smell gas do not attempt to light this appliance. 3. Verify that log placement is correct. WARNING: ANY CHANGE TO THIS HEATER OR ITS CONTROLS CAN BE DANGEROUS.
  • Page 9: Lighting Instructions

    LIGHTING INSTRUCTIONS 1. STOP! Read the safety information on reverse side of this label. 2. Make sure manual shutoff valve is fully closed. If equipped with thermostat, set to lowest setting. 3. Turn off all electrical power to appliance. 4. Open access door located at bottom of front of appliance. 5.
  • Page 10: To Turn Off Gas To Appliance

    11. Turn control knob counterclockwise to “ON”. 12. If using the unit without a wall thermostat place the Off/Manual (Off/Man) switch into the manual position. If using a wall thermostat place Auto/Off /Manual (Man) switch to Auto or Off position and place thermostat to a setting higher than room temperature.
  • Page 11: Manual Lighting Procedure

    MANUAL LIGHTING PROCEDURE 1. If pilot cannot be lit with piezo, it can be manually lit with the use of a paper match and a lighter rod. 2. Open access panel door located at bottom front of appliance. 3. Place match in holder and light. With left hand, turn control knob counterclockwise to “PILOT”position. Press in gas control knob for fi...
  • Page 12: Wiring Diagram

    WIRING DIAGRAM WARNING: CHILDREN AND ADULTS SHOULD BE ALERTED TO HAZARDS OF HIGH SURFACE TEMPERATURES AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN SAME ROOM WITH APPLIANCE WARNING: DO NOT PLACE CLOTHING OR OTHER FLAMMABLE MATERIAL ON OR NEAR APPLIANCE.
  • Page 13: Left Side

    SECTION III INSTALLATION MODEL IN SOLID FUEL BURNING FIREPLACES This model may be installed in a masonry fi replace. The fi gure below demonstrates the required dimensions. NOTE: See “Producing Adequate Air for Combustion And Ventilation” NOTE: Installer of this appliance must mechanically (peel and stick) attach marking supplied with this unvented appliance before installing to inside of fi...
  • Page 14 INSERT FIREPLACE FACADE INSTALLATION Ashley Room Heaters are available as an insert into existing masonry or factory-built fi replaces. Do not alter the existing fi replace in any way either by removing bricks or mortar which could weaken the structural integrity of the fi replace.
  • Page 15 Item Part No. Description Qty. 26412 Surround, Left 26411 Surround, Top INSERT KEYS BEHIND FLANGE OF TRIM AS 26413 Surround, Right SHOWN. BLANK CORNER KEY MUST BE IN- 891435-3 Trim, Facade Left Side STALLED FIRST. INSERT SECOND KEY. ADJUST 891435-1 Trim, Facade Top Left TRIM AND TIGHTEN SET SCREWS.
  • Page 16 SECTION IV ASSEMBLY AND INSTALLATION OF OPTIONAL WOODEN SURROUND NOTE: See section 3 for clearances. When choosing right location for your heater and surround (mantel) keep the following in mind: NOTE: Due to high temperatures, this heater should be located out of traffi c areas and away from furniture and draperies.
  • Page 17 STEP 4 STEP 5 Center and place the mantle onto the base. STEP 6 Item Part No. Description Qty. 892443.2 Base 892443.7 Left Side Wall 892443.6 Right Side Wall 1 892443.4 Front Trim 892443.5 Front Center 892443.8 Top 892443.1 Back Trim 83645 1-1/4 Wood Cabinet Screws...
  • Page 18 INSTALLATION OF OPTIONAL BRICK PANEL KIT To install the Brick Panel Kit follow the instructions below: STEP 1 Unhook gas line. Warning: Installation and service must be performed by a qualified installer, service agency, or the gas supplier. STEP 2 STEP 3 Remove gas unit by removing two screws one on Remove the fl...
  • Page 19 INSTALLATION OF OPTIONAL STAINLESS STEEL KIT To install the Stainless Steel Kit follow the instructions below: STEP 2 STEP 1 Remove the two bolts (one on the left and right Remove (4) four #10A X 1/2 HX screws and sides) that holds the burner unit in place. Remove fl...
  • Page 20: Zero Clearance Installation

    SECTION V ZERO CLEARANCE INSTALLATION The installation must conform with local codes or in the absence of local codes, with National Fuel Gas Code, ANSI Z223.1/NFPA54. This appliance may be installed in an After-Market* Manufactured (Mobile) Home, where not prohibited by state or local codes.
  • Page 21 ZERO CLEARANCE STANDOFF(S) ASSEMBLY NOTE: All Standoff must be attached to the appliance before installing as a Zero Clearance appliance. “Follow the instructions given in the diagrams below exactly”. Top Standoff (2 per unit) Side Standoff 7” (2 per unit) Back Standoff located 7”...
  • Page 22: Side View

    FIREPLACE CLEARANCES (ZC) Entire fireplace can be elevated above floor to achieve a raised hearth effect. This can be done by Fireplace may be placed directly on a combustible adding a small platform to achieve desired height. floor, against a combustible wall at marked NOTE: Wiring for lower blower must be installed during clearances or on a raised wooden platform.
  • Page 23 FINISHING YOUR FIREPLACE (ZC) There is a wide variety of fi nishing material available for your fi replace from formal wall treatments with marble and mantels, to rustic wood paneling, stone or brick. Noncombustible materials used in this installation such as slate, tile, marble, etc.
  • Page 24: Freestanding Installation

    SECTION VI FREESTANDING INSTALLATION 1. Determine exact position of your gas heater. NOTE: Due to high temperatures, this heater should be located out of traffi c areas and away from furniture and draperies. NOTE: For safe installation the minimum clearances must be met. See Figure below. 1-1/2”...
  • Page 25 FREESTANDING LEGS INSTALLATION To make this model free standing using cast legs, follow the instructions below: 1. Place heater on its back. 2. Your heater is equipped with four leg mounting nuts. Place a leg at each nut and secure leg with bolts provided.
  • Page 26: Alcove Installation

    SECTION VII ALCOVE INSTALLATION CAUTION: READ ENTIRE MANUAL BEFORE INSTALLING HEATER. 1. For clearances, see Figure below. The minimum must be met. 2. For Installation and Gas Hookup Connection see “Gas Connection” section of this manual. CAUTION: The installation must conform with local codes, or in absence of local codes, with National Fuel Gas Code, ANSI Z223.1/NFPA54.
  • Page 27: Section Viii

    SECTION VIII PRODUCING ADEQUATE AIR FOR COMBUSTION AND VENTILATION This section is for residential or manufactured (mobile) installation “This heater shall not be installed in unusually tight construction unless provisions are adequate for combustion and ventilation air.” NOTE: This heater shall not be installed in a room or space unless the required volume of indoor combustion air is provided by the method in National Fuel Gas Code, ANSIZ223.1/NFPA 54, the International Fuel Gas Code, or applicable codes.
  • Page 28 Determine the volume of the space (length x width x height). Length x Width x Height = _____________cu.ft.(volume of space) EXAMPLE: 20 ft.(Length) x 16 ft.(Width) x 8 ft.(ceiling Height)= 2560 cu. ft. (volume of space) If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.
  • Page 29: Ventilation Air From Inside Building

    SECTION IX AIR FOR COMBUSTION AND VENTILATION INSIDE BUILDING This fresh air would come from an adjoining unconfi ned space. When venting to an adjoining space, you must provide two permanent openings: one within 12" of ceiling and one within 12" of fl oor, on wall connecting two spaces.
  • Page 30: Ventilation Air From Outdoors

    SECTION X AIR FOR COMBUSTION AND VENTILATION OUTDOORS Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of ceiling and one within 12" of fl oor. Connect these items directly to outdoors. These spaces include attics and crawl spaces.
  • Page 31 SECTION XI AFTER MARKET MOBILE HOME INSTALLATION NOTE: See “Producing Adequate Air For Combustion And Ventilation” THIS APPLIANCE MAY BE INSTALLED IN AN AFTERMARKET*, PERMANENTLY LOCATED, MANUFACTURED (MOBILE) HOME, WHERE NOT PROHIBITED BY LOCAL CODES. *After Market: Completion of sale, not for purpose of resale from manufacturer. THIS APPLIANCE IS ONLY FOR USE WITH TYPE OF GAS INDICATED ON RATING PLATE.
  • Page 32: Troubleshooting

    TROUBLESHOOTING WARNING: TURN OFF, UNPLUG HEATER AND LET COOL BEFORE SERVICING. ONLY A QUALIFIED SERVICE PERSON SHOULD SERVICE AND REPAIR HEATER. CAUTION: NEVER USE A WIRE, NEEDLE OR SIMILAR OBJECT TO CLEAN ODS/PILOT. THIS CAN DAMAGE ODS/PILOT. OBSERVED PROBLEM POSSIBLE CAUSE SOLUTION Igniter button is pressed no spark Igniter electrode positioned...
  • Page 33 OBSERVED PROBLEM POSSIBLE CAUSE SOLUTION ODS/PILOT lights but fl ame goes Control knob is not fully pressed in Press control knob completely out when control knob is released Control knob not pressed in long enough After ODS/Pilot lights keep control knob pressed thirty (30) seconds Safety interlock system has been triggered (if Wait one (1) minute for safety interlock...
  • Page 34: If You Smell Gas

    WARNING: IF YOU SMELL GAS: • SHUT OFF GAS SUPPLY • DO NOT TRY TO LIGHT APPLIANCE • DO NOT TOUCH ANY ELECTRICAL SWITCH; DO NOT USE ANY PHONE IN YOUR BUILDING • IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR’S PHONE.
  • Page 35: Warranty Does Not Cover

    LIMITED WARRANTY VENT-FREE GAS LOG HEATER Ashley warrants this product to be free from defects in materials and components for two (2) years from date of fi rst purchase, provided that product has been properly installed, operated and maintained in accordance with all applicable instructions.
  • Page 36 SIT MILLIVOLT VALVE BASE...
  • Page 37: Replacement Parts

    REPLACEMENT PARTS PART NUMBER PART DESCRIPTION 81212.2 Flex Tube 89761 Piezo Ignitor 81196 Control Valve (LP) 81198 Control Valve (NAT) 81212-6 Lower Burner 81212.8 On/Off Valve 81212.14 Switch (Auto/Off/Manual) 81212.10 Primary Gas Tubes 81212.9 Male Run Tee Fitting 81212.11 Upper Burner Gas Tube 81212.12 Lower Burner Gas Tube 89921...
  • Page 38: How To Order Repair Parts

    HOW TO ORDER REPAIR PARTS THIS MANUAL WILL HELP YOU OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM YOUR APPLIANCE DEALER, AND ENABLE YOU TO ORDER REPAIR PARTS CORRECTLY. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE. WHEN WRITING, ALWAYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE HEATER.
  • Page 39 WARRANTY INFORMATION CARD Name__________________________________________ Telephone #: (_____)_____________ City____________________________________________ State_______ Zip_________________ Email Address __________________________________________________________________ Model # of Unit________________________________ Serial #___________________________ Fuel Type: Wood Coal Pellet Gas Other _________________________ Place of Purchase (Retailer)______________________________________________________ City____________________________________________ State_______ Zip_________________ If internet purchase, please list website address___________________________________ Date of Purchase _______________________________________________________________ Alternative Heat Main Heat Source...
  • Page 40   Fold Here Fold Here Fold Here PLACE STAMP HERE United States Stove Company P.O. Box 151 South Pittsburg, TN 37380...

Table of Contents