Desa LDL3924NR Owner's Operation And Installation Manual page 11

Table of Contents

Advertisement

INSTALLATION
Continued
NOTICE: Surface temperatures
of adjacent walls and mantels be-
come hot during operation. Walls
and mantels above the firebox
may become hot to the touch.
If installed properly, these tem-
peratures meet the requirement
of the national product standard.
Follow all minimum clearances
shown in this manual.
NOTICE: If your installation does
not meet the minimum clear-
ances shown, you must do one
of the following:
• operate the logs only with the
flue damper open
• raise the mantel to an accept-
able height
• remove the mantel
FLOOR CLEARANCES
A. If installing appliance on the floor level,
you.must.maintain.the.minimum.distance.
of.14".to.combustibles.(see.Figure.8).
B.. If.combustible.materials.are.less.than.14".
to the fireplace, you must install appliance
at least 5" above the combustible flooring
(see.Figure.).
Figure 8 - Minimum Fireplace Clearances If
Installed at Floor Level
Figure 9 - Minimum Fireplace Clearances
Above Combustible Flooring
111515-01J
Combustible
Material
14"
Min.
Noncombustible Material
Hearth
Combustible
Material
5"
Min.
www.desatech.com
INSTALLING DAMPER CLAMP
ACCESSORY FOR VENTED
OPERATION
Note: When used as a vented heater, ap-
pliance.must.be.installed.only.in.a.solid-fuel.
burning. fireplace. with. a. working. flue. and.
constructed.of.noncombustible.material.
You.may.use.this.heater.as.a.vented.product..
There. are. three. reasons. for. operating. your.
heater.in.the.vented.mode..
1. The fireplace does not meet the clearance
to. combustibles. requirements. for. vent-
free.operation..
.. State.or.local.codes.do.not.permit.vent-
free.operation..
3.. You.prefer.vented.operation..
If reasons number 1 or 2 above apply to you, you
must permanently open chimney flue damper.
You.must.install.the.damper.clamp.accessory.(to.
order, see Accessories, page 31). This will insure
vented.operation.(see.Figure.10)..The.damper.
clamp. will. keep. damper. open.. Installation. in-
structions.are.included.with.clamp.accessory..
See chart below for minimum permanent flue
opening. you. must. provide..Attach. damper.
clamp so the minimum permanent flue open-
ing.will.be.maintained.at.all.times..
AREA OF VARIOUS STANDARD
ROUND FLUES
Diameter
5"
6"
7"
8"
Chimney Height Minimum Permanent
6'.to.15'
15'.to.30'
Damper.
Clamp
Damper.
Clamp
Damper
Masonry.Fireplace
Figure 10 - Attaching Damper Clamp
Area
0.sq..inches
.sq..inches
3.sq..inches
51.sq..inches
Flue Opening
3.sq..inches
.sq..inches
Damper
Damper
Manufactured.
Fireplace
11