Heatilator FL92 Installation Manual page 24

Table of Contents

Advertisement

Remove 2 screws
from front & back
to lift the top off
Collar
2 in. (51 mm)
Minimum Height
Chase Top
Termination cap pipe and chimney section must overlap
Figure 5.13 Installing a TCT1175 Terra Cotta Cap
24
Place waterproof sealer
under each flange of the
termination cap and on
top of each screw to
help prevent leaks.
Termination Cap
The last section of pipe
must stop between 2 in.
(51 mm) above top of
chase and 7 in. (178 mm)
below top of chase
Chase
Chimney
Pipe
1-1/2 in. (38 mm)
Heatilator • FL92 Installation Manual • 4012-081 • Rev C • 10/03/13
Assemble
storm collar
around extended
termination cap
pipe
once cap is
installed.
Caulk gaps between
storm collar & pipe,
and storm collar
& chase top.
Collar
2 in. (51 mm)
2 in. (51 mm)
Minimum Height
7 in. (178 mm)
Chase Top
Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm)
Figure 5.14 Installing a DTO134/DTO146/DTS134/DTS146 Cap
Termination
Cap (not shown)
CT-11A
Do NOT block
Storm Collar
3 clip brackets.
Slip over chase collar
and attach with screws
14 1/2 in. (368 mm)
Chase
Chimney
Pipe
air holes
provided.
Maximum

Advertisement

Table of Contents
loading