5. Main function
4) Power-out compensation function
● If power is out on selected process, the process before power out is stored to EEPROM, once power is back
the process before power out continues.
● When power is back, washing process starts from the process at the point of the power out, rinse/drain process
starts from the initial process.
START
SAVE DATA
to EEPROM
READ DATA
RESTART
(PROCESS+TIME)
PROCESS
5) Water heater Error function
① This function starts working, when the heater works abnormally.
(this function begins sensing the heater 1 minutes later, after the heater operating)
② The value of the initial thermistor(A1) is compared with that of the thermistor(A2) in 2 minutes (Y=A2-A1)
- For 10 minutes, the variance of temperature(Y) is less than 2 ℃ "The display shows 'E5' "
message is displayed on the panel.
③ The value of the initial thermistor(A1) is compared with that of the thermistor(A2) in 2 minutes (Y=A2-A1)
- For 2 minute the variance of temperature increases more than 7 ℃ "The display shows 'E5' "
message is displayed on the panel.
④ At this time heater, Error "course led 8ea on 30 ℃ /60 ℃ led on" is displayed and all working process off
⑤ The heater operating continues during heating hours, if washing hour is left over, the residual washing process
keeps going without heating.
POWER-OUT COMPENSATION FUNCTION PROCESS
WASHING
POWER OUT
POWER BACK
MICOM RESTORE
RINSE/DRAIN
START
SAVE DATA
to EEPROM
7
RINSE/DRAIN
PROCESS
POWER OUT
POWER BACK
MICOM RESTORE
FINISH

Advertisement

Table of Contents
loading

This manual is also suitable for:

R1233gwc/ylwR833gw/ylw

Table of Contents