Setting The Time and Date—First Time Use Setting the current time and date in your meter is important if you use the meter memory. 3. Repeat step 2 to set the date and 1. Press “ ”until turning the 2. The last 2-digits of the year time.
Page 3
Setting Hypo and Hype 6. When setting is finished, 4. Press “ ” to adjust value of 5. Press “ ” to adjust value of the display will be back to hypo and Press “ ” to hype and Press “ ”...
Coding Your Meter A new Code Card is inside each new box of test strips. Code your meter every time you open a new box of test strips. 1. The display will show "no 3. The code number will be 2.
Running A Control Solution Test Squeeze the bottle until a tiny drop forms at 1. Put a test strip into the 2. Press “ ” for 1 seconds to the tip of the bottle. meter in the direction of set “ ”.
Page 6
6. A result appears on the display. Remove the test strip and throw it away after Don’t remove the test strip yet. you have compared the reading to the range Check if the reading falls within the range printed on the test strip bottle. printed on the test strip bottle.
Inserting A Lancet Into The Lancing Device You must first load the lancet into the lancing device to get it ready for use. 1. Unscrew the Cap. 2. Insert the lancet into the lancing device firmly then twist off the protective cover.
Page 8
3. Recap the front cap. 4. Select the desired penetration depth. Select 1-3 for soft or thin skin, 4-5 for average, and 6-8 for thick or calloused skin.
Page 9
5. Pull on the sliding barrel of the lancing device until it clicks and then release. Now the lancing device is ready. Do not prick your finger until your meter and strip are prepared. 6. Set the lancing device aside until later in the test.
Running A Blood Glucose Test With Blood From Your Fingertip 1. Wash your hands with soap 2. Put a test strip into the meter 3. Swab the blood collection area on and warm water. in the direction of the arrow. your finger with an alcohol swab.
Page 11
5. When the blood drop 6. Gently squeeze your finger to assist 7. The meter will beep flashes on the display, the flow of blood. This helps you get a when enough blood has obtain a drop of blood from blood drop.
Running A Blood Glucose Test With Blood From Your Forearm 1. This graphic shows where the meter cleared for alternative site testing. 2. Massage the puncture area of 3. Press and hold the device with forearm or palm for a few one clear adjustable tip against seconds.
Page 13
Running A Blood Glucose Test With Blood From Your Forearm (continued) 4. If you choose the palm, 5. Press the trigger button to 6. Hold the device against repeat step 1-3 to obtain a activate the lancing device. forearm or palm and increase drop of blood sample.
Discarding Used Lancets 1. Unscrew and remove the adjustable cap. Please discard used disposable lancets Without touching the used lancet, stick the according to the recommendations of your lancet tip into its protective cover. healthcare professional. Grip the lancet carrier firmly and pull the lancet safely out.
Viewing Test Results 1. Press “ ” to view the last 3. Press “ ” once again to 4. Press “ ” to review averages test result. view averages of 7-day of 14-day, 30-day and 90-day 2. Press “ ” to view the test result.
Setting The Alarm The meter can set up to 4 alarms, allowing you to control your test times according to your requirements. 1. Press “ ” for 5 seconds and 5. Repeat step 1 to 4 to set other 4. Press “ ” to confirm the first 3 alarm.
Screen Messages And Troubleshooting Never make treatment decisions based on an error message. If you have any concerns, please contact your local dealer. Humidified / Used strips Low power System fault Action: Replace with a Action: Replace with new Action: Replace the batteries new strip.
Page 18
System fault The "Ht" and thermometer icon The "Lt" and thermometer Action: Replace the appears. Temperature is too icon appears. Temperature is batteries first. If 005 high, outside the required too low, outside the required appears again, please range of 10°C ~40°C (50°F range of 10°C ~40°C (50°F contact your local dealer.
Page 19
Err message. Test result is higher than The test result is lower Not enough sample 600 mg/dL. than 20 mg/dL. was drawn into the test Action: Test again. If the Action: Test again. If the strip for measurement. result is still the same, result is still the same, Action: Discard the test please contact your...
Page 20
Manufacturer: EPS Bio Technology Corp. No.8, R&D RD. III, Hsinchu Science Park, Hsinchu, Taiwan 30077 TEL:+886-3-6686868 FAX:+886-3-6686866 E-mail:info@epsbio.com.tw Website:http://www.epsbio.com.tw Reference: * American Diabetes Association: Standards of Medical Care for Patients with Diabetes Mellitus, Diabetes Care, 25(2002), p.S37 0537 Obelis s.a.
Need help?
Do you have a question about the EG V1(BL) and is the answer not in the manual?
Questions and answers