Savannah Tasman DVI26,000 Installation And Operating Instructions Manual page 9

Gas fireplace 26,000 btu insert series
Hide thumbs Also See for Tasman DVI26,000:
Table of Contents

Advertisement

Press the UP or DOWN button to change the setting of P1 OFF. Press and release the SET button.
Press the UP or DOWN button to change the setting of P2 ON. Press and release the SET button.
Press the UP or DOWN button to change the setting of P2 OFF. Press and release the SET button.
Press the UP or DOWN button to change the setting of the weekend (SS) P1 ON. Press and release the
SET button.
Press the UP or DOWN button to change the setting of P1 OFF. Press and release the SET button.
Press the UP or DOWN button to change the setting of P2 ON. Press and release the SET button.
Press the UP or DOWN button to change the setting of P2 OFF. Press and release the SET button.
The Program Mode has been re-programmed.
Countdown Timer
The Countdown Timer Mode allows the control to operate the unit for up to 3 hours, in 10-minute
increments. It can be operated in either the Manual or Thermostat Modes.
To enter Timer Mode, press and release the TIMER button. The Timer icon will flash.
Press the UP or DOWN button to set the running time, in 10-minute increments. Press and release the
SET button. The timer will run for the set time duration.
Pressing the TIMER button while in Timer Mode will terminate the Timer operation. The Timer operation
will also terminate if the MODE button is cycled to off.
Thermostat Mode
The unit is placed in Thermostat Mode using the MODE button. Placing the unit in Thermostat Mode will
activate the numbers in the smaller window on the LCD screen.
Press the UP or DOWN button to change the thermostat set temperature. When the desired set
temperature appears, press and release the SET button to set.
If the SET button is not pressed, the set temperature will automatically be set after 5 seconds.
The Thermostat Mode can be de-activated by pressing the MODE button.
Thermostatic Flame Modulation
This control can perform Main Flame Modulation using the Thermostat. The control will shut the unit off
when the room temperature reaches 2° above set temperature. The Thermostat will automatically
modulate the main flame:
Manual Flame Modulation – Main Flame
To change the Flame Level manually, press the FLAME MAIN button. The current level will show in the
MAIN box on the LCD screen.
Press the UP or DOWN button to change the Flame Level.
When the unit is turned on, whether in Manual, Thermostatic, or Program Mode, the Main Flame will
automatically ignite at the High (7) setting. After 5 seconds, the flame will default to the previous setting.
Fan Control
The unit must be ON to operate the Fan.
The Fan will turn on after 5 minutes of operation. Once the Fan comes on, it can be controlled using the
FAN button.
Press the FAN button, and the fan icon and speed will appear on the LCD screen.
Press the UP or DOWN button to control the fan speed (0-6). Press the DOWN button until 0 Level is
reached to turn the Fan off.
Page 9 of 53

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Savannah Tasman DVI26,000

This manual is also suitable for:

Tasman dvi26,000rg

Table of Contents