NATURAL GAS
NOTE: An external regulator is required to reduce supply pressure to a maximum of 10
systems operating at higher pressure.
MILLIVOLT PRESSURE
Regulator Pressure Setting:
Pilot Regulator:
Gas Inlet Pressure:
PROPANE / LPG
Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c.
MILLIVOLT PRESSURE
Regulator Pressure Setting:
Gas Inlet Pressure:

IGNITION CONTROLS

Piezo ignitor allows ignition of the pilot without the use of matches.
Milli-Volt control has four (4) positions:
OFF
-
All gas to the burner is shut off at the valve.
IGN
-
Valve position to light/maintain a standing pilot.
ON
-
Valve position to turn burners ON/OFF with remote switch/thermostat.
LOW/HI -
Variable position to control flame height (heat output). Both front and rear burners are in operation to
provide realistic glow and yellow flame.
PILOT/ODS
The gas log heater is fitted with a specially designed safety pilot (ODS assembly) which senses the amount of oxygen avail-
able in the room and shuts the gas log heater off if the oxygen level begins to drop below a satisfactory level. The pilot can
only be relit when adequate fresh air is available.

THERMAL GENERATOR

The millivolt gas log pilot is fitted with a millivolt thermopile generator to provide power for remote activation.
46D0550
3.5" w.c.
3.5" w.c.
Max. 10 1/2" w. c.
Model Number
DSSNVMB
Milli-Volt
10" w.c.
Maximum 13" w.c.
Minimum 11" w.c.
Model Number
DSSPVMB
Milli-Volt
Min. 5" w.c.
Gas Rate
Type
Max. BTU/Hr Min. BTU/Hr
28,000
Gas Rate
Type
Max. BTU/Hr
28,000

PRODUCT SPECIFICATIONS

1
/
" w.c. on Natural Gas
2
18,000
Min. BTU/Hr
20,000