Milli-Volt Control Lighting Instructions; To Turn Off Gas To Heater - Monessen Hearth DSSNVMB Installation And Operating Instructions Manual

Unvented gas steel stove natural gas or propane/lpg milli-volt control
Table of Contents

Advertisement

MILLI-VOLT CONTROL LIGHTING INSTRUCTIONS

1. STOP! Read the safety information label.
2. Make sure the manual shutoff valve is fully open.
3. This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot. If piezo
ignitor does not light the pilot, refer to instructions for "Match Lighting Instructions", page 20.
4. Turn gas control knob clockwise
turn ON/OFF switch to OFF position.
5. Wait (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP!
Follow the instructions under "What To Do if You Smell Gas," page 18. If you don't smell gas, go to
next step.
6. From OFF position, turn the gas control knob counterclockwise
knob for 5 seconds. NOTE: If you are running the heater for the first time, it will be neces-
sary to press in the control knob for 30 seconds or longer to allow air to bleed out of the
gas piping.
7. With the control knob pushed in, the battery powered ignition will light the pilot.
8. Continue pushing the control knob in for a further 10 seconds to prevent the flame detector from shutting
off the gas while the probe is warming up. Release the control knob.
9. Turn gas control knob counterclockwise
10. After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF switch to ON
position or adjust thermostat to desired setting.
installed), the control knob must be set to "ON" and the ON/OFF Switch must be in the "OFF"
position.
11. If the gas logs will not operate, follow the instructions "To Turn Off Gas To Heater" below and call your
service technician or gas supplier.
Figure 17 - Pilot
1. Turn control knob clockwise
2. If applicable: Turn ON/OFF switch to OFF position and/or set thermostat (if present) to lowest setting.
3. If applicable: Turn off all electric power to the heater.
46D0550
Optional T-Stat
On/Off T-Stat
Switch

TO TURN OFF GAS TO HEATER

to OFF position to completely shut off the heater.
to the OFF position, set the thermostat to the lowest setting and
to the ON position.
NOTE: To use the optional thermostat function (if
� �
Hi/Lo Control
Ignitor/Pilot Control
Figure 18 - Control Cover Plate for Milli-Volt
OPERATING INSTRUCTIONS
to IGN position. Push in control
� �
� �
� �
� �
� �
� �
� �
� �
� �
� �
� �
� �
� �
� �
� �
� � �
� �
� �
� �
19