Checking The Burner Flame - Monessen Hearth Vent-Free Fireplace Systems DBX24C* Installation And Operating Instructions Manual

Monessen hearth vent-free fireplace systems installation and operating instructions
Table of Contents

Advertisement

CHECKING THE BURNER FLAME

OPERATING INSTRUCTIONS
Avoid any drafts that alter burner fl ame patterns. Do not allow fans to blow directly into the fireplace. Do not place
a blower inside the burn area of the firebox. Ceiling fans may create drafts that alter flame patterns. Sooting and improper
burning will result.
During manufacturing, fabricating and shipping, various components of this appliance are treated with certain oils, films or
bonding agents. These chemicals are not harmful, but may produce annoying smoke and smells as they are burned off during
the initial operation of the appliance, possibly causing headaches or eye or lung irritation. This is a normal and temporary
occurrence.
The initial break-in operation should last two to three hours with the burner at the highest setting. Provide maximum ventila-
tion by opening windows or doors to allow odors to dissipate. Any odors remaining after this initial break-in will be slight
and will disappear with continued use.
This appliance must not be used with glass doors in the closed position. This can lead to pilot outages and severe sooting
outside the fireplace.
28
33D4047

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents