Lincar Annalaura 696T Using Instructions And Maintenance

Residential space heating appliances with boiler fired by: wood
Hide thumbs Also See for Annalaura 696T:

Advertisement

Residential space heating appliances with boile r fire d by: Wood
Annalaura
Annarosa
Mod. 696T – 696TL
Mod. 697FT – 697FTL
USING INSTRUCTIONS AND MAI NTENANCE
Equipments built in conformity with European Norms for marking
Cod. 90003006 Rev. 1
1/20

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Annalaura 696T and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Lincar Annalaura 696T

  • Page 1 Residential space heating appliances with boile r fire d by: Wood Annalaura Annarosa Mod. 696T – 696TL Mod. 697FT – 697FTL USING INSTRUCTIONS AND MAI NTENANCE Equipments built in conformity with European Norms for marking Cod. 90003006 Rev. 1 1/20...
  • Page 2: Table Of Contents

    mod. 696T-696T L-697FT-697FT L GB Dear Customer, We thank You for Your preference; we try to built a product without default to make Your life easier, in any case we remember You to read this handbook before equipment using . To leave out the reading of this handbook has to be considered as “NOT CORRECT USE “...
  • Page 3: Installation

    mod. 696T-696T L-697FT-697FT L GB 1 INS TALLATION RES ERVED TO INS TALLER 1.1 Normative and prescriptions • Read carefully the contents of this handbook, it contains important information and instructions for installation, use, maintenance and product safety. • The appliance must be installed inside an environment considered suitable for installation and use by competent authorities.
  • Page 4: Connection

    mod. 696T-696T L-697FT-697FT L GB SECURITY DISTANCES • From flammable object : − A > 600 mm B > 100 mm C > 100 mm • From flammable object and from principal wall in rein forced concrete : − A > 1200 mm B >...
  • Page 5 mod. 696T-696T L-697FT-697FT L GB CHIMNEY OR FLUE • The chimney or flue should have the following characteristics: − It’ s advisable read, follow and respect what indicated in the paragraphe 1.1 − Good sel of combustion products, impermeable and completely insulated as normative condiction −...
  • Page 6 mod. 696T-696T L-697FT-697FT L GB Inclination Roof Re Flux Area Highness Z ( m) C (°) 1,85 1,00 0,50 1,50 1,30 0,80 1,30 2,00 1,50 1,20 2,50 2,10 Re-flux Chimney pot area wind damping Chimney Revolving P ot Wind chimney pot for strong Damping horizontal...
  • Page 7 mod. 696T-696T L-697FT-697FT L GB CONNECTION TO FLUE • The connect the heating equipment to the flue / chimney checking that the exhaust pipe don’t take up the free section of flue. • Employ only tubes supplied by seal gasket. •...
  • Page 8 mod. 696T-696T L-697FT-697FT L GB CONNCTION TO THE HEATING PLANT • Read carefully the contents of this handbook, it contains important information and instructions for installation, use, maintenance and product safety. The manufacturer disclaims all responsibility caused by incorrect installation, using, tampering, maintenance or no respect of normative in force.
  • Page 9: Technical Details

    mod. 696T-696T L-697FT-697FT L GB 1.5 TECHNICALS DETAILS DESCRIPTION Mod. 696T – 696TL 697FT – 697FTL Width Depth Height 1080 - 1130 1420 - 1470 Appliance weight (without water) Max. termic power output 29,7 29,7 Nominal heat output 21,1 21,1 Water heat output 16,1 16,1...
  • Page 10: Using

    mod. 696T-696T L-697FT-697FT L GB US ING - RES ERVED TO US ER 2.1 Important warnings • To read carefully this section’s instruction which are very important for use, maintenance and appliance safety. • This handbook has to be ridden completely, in case of lack it can be consider an improper use of the equipment so a not right use of it.
  • Page 11: Starting

    mod. 696T-696T L-697FT-697FT L GB • To guarantee a perfect combustion it’s necessary to preserve the wood in a dry and clean place. • The wood thermic output is related to its humidity in %. (see the schedule ). 2.3 Starting •...
  • Page 12 mod. 696T-696T L-697FT-697FT L GB IGNITION • P ut on the brazier lighting-cube or a small quantity of paper, around 0,5 kg of wood in small pieces. Put the knob of the water thermostat at max. position. Light the paper and close the foyer door.
  • Page 13 mod. 696T-696T L-697FT-697FT L GB LOADING - TO RESTART WITH EMB ERS ( Moderates flames ) In case of starting with embers, go on as follows : • Thicken the embers on center foyer . • Open the door and extract a little bit he ash drawer as shown in picture Fig. 1 •...
  • Page 14 mod. 696T-696T L-697FT-697FT L GB FIRE CONTROL The function of the thermoregulator is to regulate the quantity of primary air, this operation is effecting the intensity of the combustion and consequently the temperature of the water of the plant. MIN combustion intensity to the minimum, MAX combustion intensity to the maxi mum.
  • Page 15: Aintenance And Cleaning

    mod. 696T-696T L-697FT-697FT L GB MAINTENANCE AND CLEANING RESERVED TO USER IMPORTANT WARNING • Every maintenance and cleaning operations must be done when the stove is light off and cold. • The stove’ s conditions must be checked by our qualify staff. 3.1 Ordinary maintenance •...
  • Page 16 mod. 696T-696T L-697FT-697FT L GB Mod. 696T – 696TL - Mod. 696 FT Unscrew the fra me from the cast iron top. - Mod. 696 FTL Remove the ceramic top plate and unscrew the frame fro m the cast iron top and then unscrew the 4 screws which fix the deflector.
  • Page 17 mod. 696T-696T L-697FT-697FT L GB Mod. 697FT – 697FTL -Mod. 697FT Unscrew the frame fro m the cast iron top. -Mod. 697 FTL Remove the ceramic top plate and unscrew the frame fro m the cast iron top and then unscrew the 4 screws which fix the deflector. 1- Unscrew the rest of fixing screws of cast iron top.
  • Page 18: Accessories

    mod. 696T-696T L-697FT-697FT L GB 3.3 Accessories The following accessories are supplied with the stove : • To move residuals into the combustion chamber • For warm parts • To clean the fumes pipes into the combustion chamber 18/20...
  • Page 19: Possible Failure And Its Solution

    Every intervention must be done from qualify staff ! Lincar S.p.A is not responsible for damages to things or people due to a wrong installation, equipment tampering, improper use, bad maintenance or no observation of normative in force.
  • Page 20: Technical Data Plate

    696T-696T L-697FT-697FT L GB Technical data plate. You f ind here enclosed a copy of technical data plate. Lincar S.p.A. Via E. Fermi, 5 – 42046 Reggiolo (RE) – Italy – Tel. +39 0522 972260 – Fax +39 0522 973625 www.lincar.it info@lincar.it...

This manual is also suitable for:

Annalaura 696tlAnnarosa 697ftAnnarosa 697ftl

Table of Contents