SPECIFICATIONS

UNIT SIZE
RATINGS AND PERFORMANCE
Input Btuh*
Nonweatherized ICS
Output Capacity (Btuh)†
Nonweatherized ICS
AFUE†
Certified Temperature Rise Range --- ° F (° C)
Certified External Static Pressure
Airflow CFM‡
ELECTRICAL
Unit Volts--- Hertz--- Phase
Operating Voltage Range
Maximum Unit Amps
Maximum Wire Length (Measure one way in Ft (M)
Minimum Wire Size
Maximum Fuse or Ckt Bkr Size (Amps)**
Transformer (24v)
External Control
Power Available
Air Conditioning Blower Relay
CONTROLS
Limit Control
Heating Blower Control
Burners (Monoport)
Gas Connection Size
GAS CONTROLS
Gas Valve (Redundant)
Ignition Device
Factory-installed orifice
BLOWER DATA
Direct-Drive Motor HP (ECM)
Motor Full Load Amps
RPM (Nominal)-Speeds
Blower Wheel Diameter x Width --- In. (mm)
*
Gas input ratings are certified for elevations to 2000 ft. (610 M). In USA, for elevations above 2000 ft. (610 M), reduce ratings 4 percent for each 1000 ft. (305
M) above sea level. Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1 ---2012 Table F.4 or furnace installation instructions.
Capacity in accordance with U.S. Government DOE test procedures.
Airflow shown is for bottom only return-air supply for the as-shipped speed tap. For air delivery above 1800 CFM, see Air Delivery table for other options. A
filter is required for each return-air supply. An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16 in. wide, high efficiency
media filter.
**
Time ---delay type is recommended.
ICS Isolated Combustion System
58PHX Upflow; all 58PHA
58PHX Downflow/Horizontal
58PHX Upflow; all 58PHA
58PHX Downflow/Horizontal
Heat/Cool
Heating
Cooling
Min-Max
Heating
Cooling
Mfr.
Min. inlet pressure (In. W.C.)
Max. inlet pressure (In. W.C.)
045 -- 08
070 -- 16
090 -- 16
44,000
66,000
42,000
63,000
36,000
53,000
34,000
51,000
80.0
80.0
30-60
25--- 55
(17--- 33)
(14--- 31)
0.10/0.50
0.12/0.50
0.15/0.50
735
1230
1035
1460
115-60-1
8.1
10.8
34 (10)
26 (8)
14
15
Standard
Solid-State Time Operation
2
3
1/2-in. NPT
White-Rodgers
4.5 (Natural Gas)
13.6 (Natural Gas)
Hot Surface
1/2
3/4
6.8
8.8
10 x 6
11 x 8
(254 x 152)
(279 x 203)
(254 x 254)
4
110 -- 20
135 -- 20
88,000
110,000
132,000
84,000
105,000
126,000
72,000
90.000
107.000
69,000
86,000
102,000
80.0
80.0
80.0
35--- 65
30-60
40-70
(19--- 36)
(17--- 33)
(22--- 39)
0.20/0.50
0.20/0.50
1345
1890
1865
1665
2040
2070
104-127
11.4
14.2
14.2
25 (7)
31 (9)
31 (9)
12
20
40va
12va
35va
SPST
4
5
6
Size 43
3/4
1
1
8.8
11.5
11.5
1050--- 5
10 x 10
11 x 11
11 x 11
(279 x 279)
(279 x 279)