58SP0A/58SP1A: Product Data

SPECIFICATIONS

Unit Size
RATINGS AND PERFORMANCE
All Low NOx Upflow
*
Input Btuh
Nonweatherized ICS
Downflow/Horizontal
All Low NOx Upflow
Output Capacity (Btuh)†
Nonweatherized ICS
Downflow/Horizontal
AFUE
Certified Temperature Rise Range - °F (°C)
Certified External Static
Pressure
Airflow CFM
ELECTRICAL
Unit Volts-Hertz-Phase
Operating Voltage Range
Maximum Unit Amps
Unit Ampacity
Maximum Wire Length (Measure 1 Way in Ft (M)
Minimum Wire Size
Maximum Fuse or Ckt Bkr Size (Amps)
Transformer (24v)
External Control Power
Available
Air Conditioning Blower Relay
CONTROLS
Heating Blower Control
Burners (Monoport)
Gas Connection Size
GAS CONTROLS
Gas Valve (Redundant)
Max. inlet pressure
Ignition Device
Factory installed orifice
BLOWER DATA
Direct Drive Motor HP
Motor Full Load Amps
RPM (Nominal)Speeds
Blower Wheel Diameter x Width - In. (mm)
*. Gas input ratings are certified for elevations to 2000 ft. (610 M). In USA, For elevations above 2000 ft (610 M), reduce ratings 4 percent for each 1000 ft (305 M) above sea
level. Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1 Table F.4 or furnace installation instructions
†. Capacity in accordance with U.S. Government DOE test procedures.
‡. Airflow shown is for bottom only return-air supply. For air delivery above 1800 CFM, see Air Delivery table for other options. A filter is required for each return-air supply. An
airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16-in. (110 mm) wide, high efficiency media filter.
**. Time-delay type is recommended.
ICS = Isolated Combustion System
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
045V14-12
All Standard
44,000
All Low Nox
42,000
All Standard
35,000
All Low Nox
34,000
80.00
30-60
(17-33)
Heat/Cool
0.10/0.50
Heating
870
Cooling
1310
Min-Max
7.9
10.7
34 (10.6)
14
**
15
Heating
Cooling
2
Mfr.
Min. inlet pressure
(In. W.C.)
(In. W.C.)
1/2
6.7
1200
10 x 6
(254x152)
045V17-16
070V17-16
070V21-20
44,000
66,000
66,000
42,000
63,000
63,000
35,000
54,000
53,000
34,000
51,000
51,000
80.00
80.00
80.00
30-60
25-55
25-55
(17-33)
(14-30)
(14-30)
0.10/0.50
0.12/0.50
0.12/0.50
925
1385
1350
1720
115-60-1
104-127
7.9
10.8
10.7
14.3
34 (10.6)
25 (7.9)
33 (10.1)
14
14
15
15
40va
12va
35va
Standard
Solid State Time Operation
2
3
1/2in. NPT
WhiteRodgers
4.5 (Natural Gas)
13.6 (Natural Gas)
Hot Surface
Size 43
1/2
3/4
6.7
9.6
1200
1200
10 x 8
11 x 8
11 x 10
(254x203)
(279x203)
(254x279)
2
090V21-20
090V24-20
88,000
88,000
84,000
84,000
71,000
72,000
68,000
69,000
80.00
80.00
25-55
30-60
(14-30)
(17-33)
0.15/0.50
0.15/0.50
1425
1800
1710
2045
1915
1980
13.2
11.1
11.1
17.3
14.6
14.6
25 (7.7)
25 (7.7)
12
14
14
20
15
15
3
4
4
1
3/4
3/4
12.0
9.6
9.6
1200
1200
1200
11 X 11
11 X 11
(279x279)
(279x279)
110V24-22
110,000
105,000
90,000
86,000
80.00
30-60
(17-33)
0.20/0.50
2090
2280
13.9
18.1
31 (9.7)
12
20
5
1
12.0
1200
11 X 11
(279x279)

Advertisement

Table of Contents
loading

This manual is also suitable for:

58sp1a