F80VTL & G80VTL (Major Series B)
80% AFUE, Variable 25-Speed, ECM Motor,
Two-Stage, 4-Way Multipoise, Non-Condensing Gas Furnace
NOTE: Read the entire instruction manual before starting the
installation.
TABLE OF CONTENTS
Table 1 - Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
LOCATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Table 2 - Minimum Free Area Required for Each Combustion Air
opening of Duct to Outdoors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Table 3 - Minimum Space Volumes for 100% Combustion, Ventila-
tion, and Dilution from Indoors . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Table 4 - Opening Dimensions - In. (mm) . . . . . . . . . . . . . . . . . 11
AIR DUCTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
GAS PIPING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Table 5 - Maximum Capacity of Pipe . . . . . . . . . . . . . . . . . . . . . 14
Table 6 - Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
VENTING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Table 7 - Combined Appliance Maximum Input Rating
Table 8 - Minimum Allowable Input Rating of
Table 9 - Recommended Minimum Vent Height Per Furnace and Vent
Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Table 10 - Air Delivery - CFM (with Filter)* . . . . . . . . . . . . . . . 25
Table 11 - Default Airflow Settings . . . . . . . . . . . . . . . . . . . . . . 27
AND NAVIGATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Table 12 - System Status Display Codes. . . . . . . . . . . . . . . . . . . 27
Table 13 - Main Menu Options . . . . . . . . . . . . . . . . . . . . . . . . . . 28
SERVICE LABEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Table 14 - Test Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Table 15 - Altitude Derate Multiplier for U.S.A. . . . . . . . . . . . . 32
Portions of the text and tables are reprinted from NFPA 54/ANSI Z223.1E, with permission of National Fire Protection Association, Quincy, MA
02269 and American Gas Association, Washington DC 20001. This reprinted material is not the complete and official position of the NFPA or ANSI
Installation, Start-up, Operating and
Service and Maintenance Instructions
on the referenced subject, which is represented only by the standard in its entirety.
Table 16 - Gas Rate (CU ft./hr). . . . . . . . . . . . . . . . . . . . . . . . . . 33
Table 17 - Orifice Size and Manifold Pressure (in. w.c.) for Gas Input
Rate (Tabulated Data Based on 22,000 BTUh High-Heat/14,500
Table 18 - Orifice Size and Manifold Pressure (in. w.c.) for Gas Input
Rate (Tabulated Data Based on 21,000 BTUh High-Heat/14,500
Table 19 - Filter Size Information - In. (mm) . . . . . . . . . . . . . . . 40
Table 20 - Filter Size Information - In. (mm) . . . . . . . . . . . . . . . 40
To learn more about this appliance and installation via a mobile device,
go to
http://www.fasthvacrparts.com/NFC
access airflow tables or troubleshooting guide on your mobile device go
to
mlctraining.com/training/techdocs/77/
or use the QR code below. To
or use the QR code below.