Panasonic CS-VA75KE Service Manual page 73

Hide thumbs Also See for CS-VA75KE:
Table of Contents

Advertisement

Attached accessories
Applicable piping kit
CZ-3F5, 7AEN (CS/CU-VA75KE, VA95KE)
CZ-4F5, 7, 10AN (CS/CU-VA125KE)
SELECT THE BEST LOCATION
INDOOR UNIT
• There should not be any heat source or steam near the
unit.
• There should not be any obstacles blocking the air
circulation.
• A place where air circulation in the room is good.
• A place where drainage can be easily done.
• A place
where
noise
consideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the wall,
ceiling, or other obstacles.
• Indoor unit of this room air conditioner shall be installed
on the wall in a height of at least 2.3 m.
OUTDOOR UNIT
• If an awning is built over the unit to prevent direct
sunlight or rain, be careful that heat radiation from the
condenser is not obstructed.
• There should not be any animal or plant which could be
affected by hot air discharged.
• Keep the spaces indicated by arrows from wall, ceiling,
fence or other obstacles.
• Do not place any obstacles which may cause a short
circuit of the discharged air.
Piping size Common
Model
Gas Liquid
VA75KE/95KE 3/8"
1/4"
VA125KE
1/2"
1/4"
prevention
is
taken into
Max.
Max.
Additional
Length
Elevation
Piping
Refrigerant
(m)
Length
(g/m)
(m)
7.5
5
10
7.5
5
15
CS-VA75KE CU-VA75KE / CS-VA95KE CU-VA95KE / CS-VA125KE CU-VA125KE
Indoor/Outdoor unit installation diagram
• This illustration is for explanation purposes only.
30
The indoor unit will actually face a different way.
73

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu-va75keCs-va95keCs-va125keCu-va125keCu-va95ke

Table of Contents