OPTIONAL FAN/BLOWER SYSTEM
Finishing
1. Re-install the lower access panel.
. To use the blower, turn the knob on the speed control clockwise. The blower should be operating at
the highest speed. Continue to turn the knob until it reaches the desired speed.
NOTE: Some older units are not equipped with mounting brackets. Velcro and magnets are
used to mount blowers to sidewall and floor.
Electrical Grounding Instructions: This appliance is
equipped with a three-prong (grounding) plug for
your protection against shock hazard and should
be plugged directly into a properly grounded three
prong receptacle.
75D0004
Variable
Fan Control
1
OFF
110/115V AC
Blower Plug
Black
White
Green
Figure 51 -
Blower Wiring Diagram
FP1910
SC blower wiring diagram
8/08
Thermal
White
Sensor
(Hi Temp)
2
ON
Black
Blower
Motor
MLDV Series Gas Fireplace
Blower
Motor
White
33