VENTING INSTALLATION
VERTICAL (THROUGH-THE-ROOF) APPLICATIONS (continued)
This Gas Fireplace has been approved for,
Vertical installations up to 40' (1 m) in height. Up to a 10' (3 m) horizontal vent run can be installed
within the vent system using a maximum of two 90° elbows. Figure 30
40' Max. Height
8' Min. Height
Figure 30 -
Support Straps for Horizontal Runs
Up to two 45° elbows may be used within the horizontal
run. For each 45° elbow used on the horizontal plane,
the maximum horizontal length must be reduced by
FP1183
18" (450 mm).
max height
Example: Maximum horizontal length
No elbows
= 10' (3 m)
1 x 45° elbows
= 8.5' (.6 m)
 x 45° elbows
= 7' (.1 m)
A minimum of an 8' (.5 m) vertical rise is required.
Two sets of 45°elbows offsets may be used within the
vertical sections. From 0 to a maximum of 8' (.5 m)
of vent pipe can be used between elbows. Figure 31
Determine the roof pitch and use the appropriate
starter kit for offset installation.
The maximum angular variation allowed in the system
is 70°. Figure 31
The minimum height of the vent above the highest
point of penetration through the roof is ' (610 mm).
75D0004
10'
Maximum
Support Straps
Every 3'
40' Max. Height
8' Min. Height
1
2
3
4
Example:
Elbow 1
Elbow 
Elbow 3
Elbow 4
Total Angular Variation
Figure 31 -
Maximum Elbow Usage
FP1179
max bends
MLDV Series Gas Fireplace
10'
Maximum
Support Straps
Every 3'
FP1183
1
2
3
=
90°
4
=
45°
=
45°
=
90°
=
70°
3