Summary of Contents for Vectaire ELEGANCE EL1003DT

  • Page 1 ELEGANCE Low Carbon Fan with EC Motor Installation and Operating Instructions • 6 models: - SAP Appendix Q Eligible 3 speed continuous running - timer - humidity control - SELV - low voltage • for all domestic wet rooms • for walls, ceilings or windows IPX4 IPX7...
  • Page 2 "Elegance” - HIGH PERFORMANCE, LOW CARBON FANS INSTALLATION and OPERATING INSTRUCTIONS THIS LEAFLET MUST BE AVAILABLE TO THE USER The product you have purchased is an extractor fan - do not touch it with wet or damp parts of the for exhausting directly outside or through medium body (e.g hands, feet).
  • Page 3 WARNING: Damage could be caused to the product in stoves or other combustion-powered if the installation instructions are not followed devices. • The product should not be used in an ambient RANGE temperature higher than 40°C (104°F). • The product should not be exposed to atmos- Trickle Speed 1- 8 lt/sec - 28.8 m³/h pheric agents (rain, sun, snow, etc.).
  • Page 4: Installation

    adjustable over-run timer (adjustable from 0 to 30 minutes) has completed its cycle. The boost speed can also be activated by as described for model EL1003DT EL1003HDTLV - SELV, 12v version of EL1003HDT INSTALLATION...
  • Page 6 INSTALLATION check there is nothing missing in box remove front cover drill hole in wall - allow extra width if using ducting - it is the installer's responsibility to use the appropriate core cutter to obtain the correct hole diameter. use fan assembly as template to mark drill holes drill 4 x 6mm dia holes...
  • Page 7: Wiring Diagrams

    JUMPER SWITCH These fans are designed to run continuously at one of 2 lower speeds fixed at installation using the jumper switch. EL1003, EL1003DT and EL1003HDT: Minimum Speed 1 - Jumper 2 in Minimum Speed 2 - Jumper 2 out To activate delay-on timer in EL1003DT and EL1003HDT, remove Jumper 3 (N.B Jumpers 1 and 3 will be pre-set at the factory, depending on the...
  • Page 8: Maintenance

    DISMANTLING & RECYCLING This product has been designed and constructed using high-quality materials and components that can be recycled or re-used. Vectaire Ltd, Lincoln Road, Cressex Business Park, High Wycombe, Buckinghamshire, HP12 3RH Tel: +44 (0)1494 522333. Fax: +44 (0)1494 522337.