Please complete this information and retain this manual for the life of the equipment. For Warranty
Service and/or parts, this information is required.
Model Number
WARNING: For your safety, do not store or use gasoline or other flammable vapors or
liquids in the vicinity of this or any other appliances. Keep the area free and clear of
combustible. (See ANSI Z83. 14B, 1991).
WARNING:Improper installation, adjustment, alteration, service or maintenance can
cause property damage, injury, or death. Read the installation, operating and
maintenance instructions thoroughly before installing, or servicing this equipment.
WARNING:Instructions must be posted in a prominent location. All safety precautions
must be taken in the event the user smells gas. Safety information can be obtained from
your local gas supplier.
CAUTION: These models are designed, built, and sold for commercial use only. If these
models are positioned so the general public can use the equipment, make sure that
cautions, warnings, and operating instructions are clearly posted near each unit so that
anyone using the equipment will use it correctly and not injure themselves or harm the
equipment.
The appliance and it's individual shutoff valve (to be supplied by user) must be disconnected from
the gas supply piping system during any pressure testing of that system at test pressures in excess of
½ psi (3.45 kPa).
The appliance must be isolated from the gas supply piping system by closing it's individual manual
shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to
or less than ½ psi (3.45 kPa).
WARNING:A factory authorized agent should handle all maintenance and repair. Before
doing any maintenance or repair, contact your authorized service representative.
IMPORTANT FOR FUTURE REFERENCE
Serial Number
GAS PRESSURE
Conforms to ANSI STD
Z83.11b-2009(R2012)
Certified to CSA
STD 1.8b-2009(R2012)
1
Date Purchased

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HP212 and is the answer not in the manual?

Questions and answers

Summary of Contents for CPG HP212

  • Page 1 Certified to CSA STD 1.8b-2009(R2012) Installation & Operation Instructions Model: HP212, HP424, HP636 IMPORTANT FOR FUTURE REFERENCE Please complete this information and retain this manual for the life of the equipment. For Warranty Service and/or parts, this information is required.
  • Page 2: Table Of Contents

    Congratulations on your purchase of Cooking Performance Group commercial cooking equipment. Cooking Performance Group takes pride in the design and quality of our products. When used as intended and with proper care and maintenance, you will experience years of reliable operation from this equipment.
  • Page 3: Safety Precautions

    LOCATION OF DATA PLATE The data plate is located on the side panel. IMMEDIATELY INSPECT FOR SHIPPING DAMAGE All equipment should be examined for damage before and during unloading. The freight carrier has assumed responsibility for its safe transit and delivery. If equipment is received damaged, either apparent or concealed, a claim must be made with the delivering carrier.
  • Page 4: General Installation Instructions

    SPECIFICATIONS AND DIMENSIONS MODEL WIDTH DEPTH HEIGHT # OF BTU/PER TOTAL W.C. IN. (MM) IN. (MM) IN. (MM) BURNERS NAT/LP BTU/ Hr HP212 12(305) 26.8(680) 15(380) 22,000 44,000 6/10 HP424 26.8(680) 15(380) 22,000 88,000 6/10 24(610) 22,000 6/10...
  • Page 5: Conversion

    CONVERSION Instructions are for conversion from Natural Gas to Propane (L.P.) on all models. The conversion should be done before connecting the unit to the gas supply. Units are shipped from the factory equipped for use on natural gas. Orifices necessary for LP (propane) are provided in a bag tied to the valve on the front panel.
  • Page 6: Lighting Instructions

    LIGHTING INSTRUCTIONS Lighting pilot The pilot light on the appliance has been set at the factory. A screwdriver may be required for the first lighting to adjust the flame for your elevation. 1. Turn off the manual valve and wait 5 minutes to clear the gas. 2.
  • Page 7: Cleaning & Maintenance

    CLEANING & MAINTENANCE CAUTION: Use only non-abrasive cleaners. Abrasive cleaners could scratch the finish of your unit, marring its appearance and making it susceptible to dirt accumulation. Do not use steel wool, other abrasive cleaners or cleaners/sanitizers containing chlorine, iodine, ammonia or bromine chemicals as these will deteriorate the stainless steel and glass material and shorten the life of the unit.
  • Page 8: Explosion View Drawing

    EXPLOSION VIEW DRAWING MODEL: HP424...
  • Page 9: Spare Part List

    Spare Parts List DESCRIPTION MODEL CODE HP212 Grate HP424 01.03.1015096 HP636 HP212 01.03.1015025 Burner HP424 01.02.1005305 HP636 HP212 Regulator HP424 01.22.1069501 HP636 HP212 01.05.1029410 Tray HP424 01.05.1029318 HP636 01.05.1029365 HP212 Foot HP424 01.02.1005373 HP636 HP212 Main pipe assy.-Front HP424 06.05.1472181...
  • Page 10 HP212-NAT HP424-NAT 01.20.1068646 HP636-NAT Orifice HP212-LPG HP424-LPG 01.20.1068654 HP636-LPG HP212 Dial HP424 01.02.1005392 HP636 HP212 Connector 01.02.1005184 HP424 HP636 Cooking Performance Group Lancaster, Pennsylvania Website: www.CookingPerformanceGroup.com...
  • Page 12: Limited Warranty

    Cooking Performance Group Cooking Equipment Models: Griddles: G15, G24, G36, G48, G15T, G24T, G36T, G48T Charbroilers: CBL15, CBL24, CBL36, CBL48, CBR15, CBR24, CBR36, CBR48 Hot Plates: HP212, HP424, HP636 Fryers: CF15, CF30 All new Cooking Performance Group Griddles, Charbroilers, Hot Plates, and Fryers used for commercial purpose are warranted against defects in materials and workmanship under normal use and maintenance.