ELECTRICAL INSTALLATION

Wall
Switch
Figure 15 -
Wiring Diagram
Label all wires prior to disconnection when
servicing controls. Wiring errors can cause
improper and dangerous operation. Verify
proper operation after servicing.
CONNECTING OPTIONAL WALL SWITCH
1. Use 18 awg, two-wire cable, 15 feet maximum length.
. At one end of the cable, connect both wires to the wall switch or thermostat. At the other end,
connect one wire to TP/TH and one wire to TH. The color of the wires does not matter.
33D4047
On/Off
Switch
TH = 3
TP = 1
TP/TH = 
DFX & DBX Series Vent Free Fireplaces
On/Off
Switch
ODS
Pilot
Valve
Spade
Terminal
Switch
FP2112
wiring diagram
12/08
ODS Pilot
FP11
Optional Wall
Switch or Remote Receiver