Dialight D1RW-C13-006 Installation And Maintenance Manual page 7

Dual white strobe & red beacon
Table of Contents

Advertisement

_____________________________________________________________________
EARTH/GROUND
NEUTRAL
LIVE
DAY/NIGHT
SYNC
DIM0
DIM1
RED FAULT A
RED FAULT B
WHITE FAULT A
WHITE FAULT B
Notes:
1: After initial power up there may be a few seconds of delay before flashing
begins.
2: The default red Beacon and White Strobe flash rate is 20 flashes per minute.
3: The sync signal is not required if there is no need to synchronize with another
strobe. In the absence of a sync signal, the Strobe and Red Beacon will default
to 20 FPM.
4: For maximum immunity from the effects of radiated interference, the cable
from the Control Box to Power Supply Cabinet should be shielded with the
screen grounded at both ends.
_____________________________________________________________________________
Dialight Corporation 1501 Route 34 South
Tel: 732.919.3119 Fax:732.751.5778 Web: www.dialight.com
Terminal Block Connections
Safety Earth/Ground
Neutral supply conductor
100-240Vac, Live supply conductor
Connect to live for Night Mode
Pulse from live at desired flash rate to synchronize, or
connect constantly to live for steady Red Beacon
Connect Dim 0 to live for 30%, connect Dim 0 and 1 to live
for 10%
Connect Dim 0 to live for 30%, connect Dim 0 and 1 to live
for 10%
Uncommitted solid state relay output (600V/40mA max,
20mA continuous)
Uncommitted solid state relay output (600V/40mA max,
20mA continuous)
Uncommitted solid state relay output (600V/40mA max,
20mA continuous)
Uncommitted solid state relay output (600V/40mA max,
20mA continuous)
Sheet 7 of 14
Document No.
9100-127-1109-99 Rev A
Release Date: Sept 11, 2007
Farmingdale NJ 07727

Advertisement

Table of Contents
loading

This manual is also suitable for:

D1rw-g13-006

Table of Contents