FOR USE OF OPTIONAL AK-4 OUTSIDE AIR KIT
COMBUSTION AIR
1. Locate combustion air assembly at an exterior location which is not likely to be accidentally blocked in any
manner. Locate assembly a min. of 12" above the snow line to prevent blockage by snow accumulation.
2. Never mount the combustion air inlet assembly in a garage or storage area where combustible fumes such
as gasoline might be drawn into the fireplace.
3. Combustion air can be drawn from the crawl space under a house when an adequate supply of air is provided
by open ventilation.
4. CAUTION: Do not take combustion air from attic space or garage space.
5.
Locate air supply inlet at least 3' away from any appliance vent terminal.
6. Avoid extremely long runs and numerous turns in the duct leading from the fireplace to the combustion air
assembly. These conditions increase the resistance to the free flow of air through the duct. See Figures 14
through 17 for methods of installing the outside air for combustion assemblies.
Note: Fireplace model in illustrations may not be representative of your appliance.
Above
Snow
Level
Ground
Level
Figure 14 - Basement Installation
Duct Extended
to Miss Joist
To Outside Wall
Figure 16 - Installation Above Basement or
Crawl Space
16
Basement
Wall
Inlet Grill in
8'max.
Soffit
(Overhang)
Figure 15 - Concrete Slab Installation
Outside
Wall
(Optional Outside Air Runs)
Inside Wall
Figure 17 - 45° Corner Installation on
Slab Floor
61D1013