23) Indoor humidity low alarm: 1%  99% (default: 35%, disable)
24) Outdoor temperature high alarm: -40.0  60.0C (-40F  140F) (default: 30.0C,
disable)
25) Outdoor temperature low alarm: -40.0  60.0C (-40F  140F) (default: -10.0C,
disable)
26) Outdoor humidity high alarm: 1%  99% (default: 75%, disable)
27) Outdoor humidity low alarm: 1%  99% (default: 45%, disable)
28) Wind chill temperature low alarm: -40.0  60.0C (-40F  140F) (default: 0.0C,
disable)
29) Dew point temperature high alarm: -40.0  60.0C (-40F  140F) (default: 10.0C,
disable)
30) Dew point temperature low alarm: -40.0  60.0C (-40F  140F) (default: -10.0C,
disable)
31) Heat index temperature high alarm: -40.0  60.0C (-40F  140F) (default: 27.0C,
disable)
32) Rainfall alarm: rainfall rate and rainfall 24H: 0-999.9mm (default: 0.0mm, disable)
33) Wind speed alarm: 0-50.0m/s (default: 1.8km/h, disable)
34) Guest speed alarm: 0-50.0m/s (default: 3.6km/h, disable)
35) Light high alarm: 0 to 300000 (default: 200000lux, disable)
36) UVI high alarm: 0 to 15 (default: 10, disable)
USA (WWVB) Version (difference with EU version):
1)
Time zone: default -5
2)
12/24 hour format: default 12hr
3)
DD-MM-YYYY / MM-DD-YYYY / YYYY-MM-DD format (default: MM-DD-YYYY)
4)
Temperature unit: F
5)
Pressure unit: inHg
6)
Wind speed unit: mph
7)
Rain fall unit: inch
Specifications
1)
Indoor temperature measure range: -40 to 60C
2)
Outdoor temperature measure range: -40 to 60C
3)
Humidity measuring range: 1% to 99%
4)
Wind speed measure range: 0 to 50.0m/s
5)
Wind direction: 0 to 359 degree
6)
Rainfall range: 0 to 9999.9 mm
7)
Light range: 0 to 300000.0 lux
8)
UVI range: 0 to 15 index (0 to 20000 w/m2)
20