Operation Sequence - Sharp R-310B Service Manual

Table of Contents

Advertisement

R-310B
OFF CONDITION
Closing the door activates all door interlock switches
(1st. latch switch, 2nd. latch switch and stop switch).
IMPORTANT
When the oven door is closed, the monitor switch contacts
(COM-NC) must be open.
When the microwave oven is plugged in a wall outlet, rated
voltage is supplied to the point A3+A5 in the control unit.
Figure O-1 on page 25
NOTE: When the oven door is opened, the oven lamp
comes on at this time.
MICROWAVE COOKING CONDITION
HIGH COOKING
Set the variable cooking control to HIGH. When the Light
Up Dial is turned, the following operations occur;
Function sequence
Figure O-2 on page 25
CONNECTED COMPONENTS
Oven lamp, Fan motor, Turntable motor
Power transformer
1. Rated voltage is supplied to the primary winding of the
power transformer. The voltage is converted to about
3.3 volts A.C. output on the filament winding and high
voltage of approximately 2000 volts A.C. on the
secondary winding.
2. The filament winding voltage (3.3 volts) heats the
magnetron filament and the high voltage (2000 volts) is
sent to the voltage doubling circuit, where it is doubled
to negative voltage of approximately 4000 volts D.C..
3. The 2450 MHz microwave energy produced in the
magnetron generates a wave length of 12.24 cm. This
energy is channeled through the waveguide (transport
channel) into the oven cavity, where the food is placed
to be cooked.
4. When the cooking time is up, a signal tone is heard and
the relays RY1+RY2 go back to their home position.
The circuits to the oven lamp, power transformer, fan
motor and turntable motor are cut off.
5. When the door is opened during a cook cycle, the
switches come to the following condition
SWITCH
CONTACT
1st. latch switch
COM-NO
2nd. latch switch
COM-NO
Monitor switch
COM-NC
Stop switch
COM-NO
The circuits to the power transformer, fan motor and
turntable motor are cut off when the 1st. latch switch,
2nd. latch switch, and stop switch are made open. The
oven lamp remains on even if the oven door is opened
after the cooking cycle has been interrupted, because
the relay RY1 stays closed. Shown in the display is the
remaining time.

OPERATION SEQUENCE

RELAY
RY1
RY2
CONDITION
DURING
DOOR OPEN
COOKING
(NO COOKING)
Closed
Open
Closed
Open
Open
Closed
Closed
Open
6.
MONITOR SWITCH CIRCUIT
The monitor switch is mechanically controlled by
oven door, and monitors the operation of the 1st and
2nd. latch switches.
6-1 When the oven door is opened during or after the
cycle of a cooking program, the 1st. latch switch, 2nd.
latch switch and stop switch must open their contacts
first.
After that the contacts (COM-NC) of the monitor
switch can be closed.
6-2. When the oven door is closed, the contacts (COM-
NC) of the monitor switch must be opened. After that
the contacts of the 1st. latch switch, 2nd. latch switch
and stop switch are closed.
6-3. When the oven door is opened and the contacts of
the1st. latch switch and 2nd. latch switch remain
closed, the fuse M8A will blow. Because the monitor
switch is closed and a short circuit is caused.
MEDIUM HIGH, MEDIUM, MEDIUM LOW, LOW
COOKING
When the microwave oven is preset for variable cooking
power, 230-240 volts A.C. power is supplied to the power
transformer intermittently within a 32-second time base
through the relay contact which is coupled with the cur-
rent-limiting relay. The following levels of microwave power
are given.
SETTING;
HIGH
MEDIUM HIGH
MEDIUM
MEDIUM LOW
LOW
NOTE: The ON/OFF time ratio does not exactly correspond
to the percentage of microwave power, because
approx. 2 seconds are needed for heating up the
magnetron filament.
4
32 sec. ON
8 sec. OFF
24 sec. ON
Approx. 70%
18 sec. ON
14 sec. OFF
Approx. 50%
12 sec. ON
20 sec. OFF
Approx. 30%
6 sec. ON
26 sec. OFF
Approx. 10%

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents