Operation Sequence - Sharp R-241CWAA Service Manual

Table of Contents

Advertisement

R-241CWAA
R-241CWAC
R-241CWAP
OFF CONDITION
Closing the door activates all door interlock switches
(1st. latch switch, 2nd. interlock relay control switch).
IMPORTANT
When the oven door is closed, the monitor switch contacts
(COM-NC) must be open.
When the microwave oven is plugged in a wall outlet, rated
voltage is supplied to the control unit.
Figure O-1 on page 25
1. The display flashes "88:88".
2. To set any programmes or set the clock, you must first
touch the stop/ clear pad.
3. " : " appears in the display.
NOTE: When the oven door is opened, the oven lamp
comes on at this time.
MICROWAVE COOKING CONDITION
HIGH COOKING
Enter a desired cooking time with the touching the number
keys and start the oven with touching the start key.
Function sequence
Figure O-2 on page 25
CONNECTED COMPONENTS
Oven lamp, Fan motor, Turntable motor
Power transformer
1. Rated voltage is supplied to the primary winding of the
power transformer. The voltage is converted to about 3.3
volts A.C. output on the filament winding and high voltage
of approximately 2000 volts A.C. on the secondary
winding.
2. The filament winding voltage (3.3 volts) heats the
magnetron filament and the high voltage (2000 volts) is
sent to the voltage doubling circuit, where it is doubled to
negative voltage of approximately 4000 volts D.C..
3. The 2450 MHz microwave energy produced in the
magnetron generates a wave length of 12.24 cm. This
energy is channelled through the waveguide (transport
channel) into the oven cavity, where the food is placed to
be cooked.
4. When the cooking time is up, a signal tone is heard and
the relays RY1+RY2 go back to their home position. The
circuits to the oven lamp, power transformer, fan motor
and turntable motor are cut off.
5. When the door is opened during a cook cycle, the
switches come to the following condition.
SWITCH
CONTACT
1st. latch switches COM-NO
2nd. interlock relay
COM-NO
control switch
Monitor switch
COM-NC

OPERATION SEQUENCE

RELAY
RY1
RY2
CONDITION
DURING
DOOR OPEN
COOKING
(NO COOKING)
Closed
Open
Closed
Open
Open
Closed
The circuits to the power transformer, fan motor and
turntable motor are cut off when the 1st. latch switch and
2nd. interlock relay control switch are made open.
The oven lamp remains on even if the oven door is
opened after the cooking cycle has been interrupted,
because the relay RY1 stays closed. Shown in the
display is the remaining time.
6. MONITOR SWITCH CIRCUIT
The monitor switch is mechanically controlled by oven
door, and monitors the operation of the 1st. latch switch
and the 2nd. interlock relay.
6-1 When the oven door is opened during or after the cycle
of a cooking program, the 1st. latch switch and 2nd.
interlock relay control switch must open their contacts
first. After that the contacts (COM-NC) of the monitor
switch can be closed.
6-2. When the oven door is closed, the contacts (COM-NC)
of the monitor switch must be opened. After that the
contacts of the 1st. latch switch and 2nd. interlock relay
control switch are closed.
6-3. When the oven door is opened and the contacts of the
1st latch switch and 2nd. interlock relay remain closed.
The fuse M8A will blow, because the monitor switch is
closed and a short circuit is caused.
MEDIUM HIGH, MEDIUM, MEDIUM LOW, LOW
COOKING
When the microwave oven is preset for variable cooking
power, rated voltage is supplied to the power transformer
intermittently within a 32-second time base through the relay
contact which is coupled with the current-limiting relay. The
following levels of microwave power are given.
SETTING;
HIGH
MEDIUM HIGH
MEDIUM
MEDIUM LOW
LOW
NOTE: The ON/OFF time ratio does not exactly correspond
to the percentage of microwave power, because
approx. 2 seconds are needed for heating up the
magnetron filament.
4
32 sec. ON
8 sec. OFF
24 sec. ON
Approx. 70%
18 sec. ON
14 sec. OFF
Approx. 50%
12 sec. ON
20 sec. OFF
Approx. 30%
6 sec. ON
26 sec. OFF
Approx. 10%