Section 4: Servicing; Pump Disassembly - Pentair Pool Products SuperFlo Installation And User Manual

Hide thumbs Also See for SuperFlo:
Table of Contents

Advertisement

8
Section 4
Servicing
This section describes how to service the SuperFlo
WARNING — Risk of electrical shock or electrocution.
This pool pump must be installed by a licensed or certified electrician or a qualified pool serviceman in
accordance with the National Electrical Code and all applicable local codes and ordinances. Improper
installation will create an electrical hazard which could result in death or serious injury to pool users,
installers, or others due to electrical shock, and may also cause damage to property.
Always disconnect power to the pool pump at the circuit breaker before servicing the pump. Failure to
do so could result in death or serious injury to serviceman, pool users or others due to electric shock.
Read all servicing instructions before working on the pump.
WARNING — DO NOT open the strainer pot if pump fails to prime or if pump has been operating without water in
the strainer pot. Pumps operated in these circumstances may experience a build up of vapor pressure
and may contain scalding hot water. Opening the pump may cause serious personal injury. In order
to avoid the possibility of personal injury, make sure the suction and discharge valves are open and
strainer pot temperature is cool to touch, then open with extreme caution.
CAUTION — Be sure not to scratch or mar the polished shaft seal faces; seal will leak if faces are damaged.

Pump Disassembly

1. All moving parts are located in the rear sub-assembly of this pump.
Required Tools:
1/4 inch socket or open end wrench.
3/8 inch socket or open end wrench.
9/16 inch open end wrench.
Flat blade screwdriver.
2. To remove and repair the motor sub-assembly perform the following procedures:
a. Turn off the pump circuit breaker at the main panel.
b. Drain the pump by removing the drain plugs.
c. Remove the 4 bolts that hold the main pump body (strainer pot/volute) to the rear sub-assembly.
d. GENTLY pull the two pump halves apart, removing the rear sub-assembly.
e. Remove the three hex head screws holding the diffuser in position.
f.
Hold the impeller securely in place and remove the impeller lock screw by using a flat blade screwdriver
or wrench. The screw is a left-handed thread and loosens in a clockwise direction.
g. Remove the shaft cap located at the back of the motor and hold the shaft secure with a ½ inch (Century
motors) or 7/16 inch (Franklin Electric
motor canopy, move the capacitor to one side and hold the shaft with a 7/16 inch open-end wrench.
h. To unscrew the impeller from the shaft, twist the impeller counter-clockwise.
i.
Remove the four bolts from the seal plate to the motor using a 3/8 inch wrench.
j.
Place the seal plate face down on a flat surface and tap out the ceramic seal.
k. Clean the seal plate, seal housing, and the motor shaft.