Note: Follow the disassembly procedure in the numerical order given.
HOW TO OPEN THE LOADING ASSY PANEL WHEN POWER SWITCH TURNS OFF
DMB10 BOARD SERVICE POSITION
• In checking the DMB10 board, prepare four extension jigs (Part No. J-2501-239-A: 1.00 mm Pitch, 5 cores, Length 300 mm, Part No.
J-2501-242-A: 1.00 mm Pitch, 11 cores, Length 300 mm and Part No. J-2501-280-A: 5 cores, Length 300 mm).
Connect extension jig (J-2501-242-A) to the
MAIN board (CN503) and DMB10 board (CN106).
DMB10 board
(CN202)
DMB10 board
(CN101)
wire (flat type) 24 core
Note: Don't remove the
wire (flat type) 24 core (CN101).
If you remove the
wire (flat type) 24 core (CN101),
solder the bridge of optical pick-up.
Connect extension jig (J-2501-239-A) to the
DMB10 board (CN202) and MS-203 (CN001) board.
2 Slide the chuck cam in the direction
DMB10 board
DMB10 board
(CN401)
(CN106)
MS-203 board
(CN001)
of arrow to release the chucking.
1 Open the cover dust.
3 Draw out the loading assy panel
in the direction of the arrow.
DMB10 board
(CN4501)
Connect extension jig (J-2501-280-A) to the
MAIN board (CN508) and DMB10 board (CN401).
Connect extension jig (J-2501-242-A) to the
MAIN board (CN504) and DMB10 board (CN4501).
MAIN board
(CN504)
HCD-X1
MAIN board
(CN508)
MAIN board
(CN503)