Item
Connector (1)
Actuator cable connection (2)
Actuator general condition
Checking actuators with DiaSys®
Note:
For installation position of exhaust flaps, refer to overview (→ Page 144).
1.
Switch on ECU.
2.
Carry out actuator test with DiaSys® (teach-in routine) (→ manufacturer's documentation).
192 | Task Description | MS150112/01E 2014-10
Findings
Damaged
Damaged, protective cap not seat-
ed correctly.
Heavily contaminated by black ex-
haust.
Action
Replace
Replace, fit protective cap correct-
ly.
Replace