OPERATION
Blue/
Red/Green
Blue/
Red/Green
Emergency ON/OFF Switch
This switch is used when unit needs temporary on/off.
When press emergency button, unit starts running. The
running mode and fan speed mode are set at auto.
Press emergency button again, unit stops running.

LED Screen

Please refer to below chart for detail.
Note: Orange LED presents Red/Green lights up
simultaneously.
Running mode
Cooling mode(Blue)
Dehumidify mode(Orange)
Note: Under AUTO mode, unit will change its
running mode.
Running and TIMER "off"
Cooling mode(Blue)
Dehumidify mode(Orange)
Note: Under AUTO mode, unit will change its
running mode.
Stand-by and TIMER "on"
All mode
Water tank full
Note: Water tank full, red LED indicator flashes. When
water full, unit stops running, After discharge
water from tank, please press power on/off
button to operate the units and unit will be in
the mode before water tank full.
indicator
indicator
Fan mode(Green)
Fan mode(Green)
Blue indicator

Emergency switch

Fiter Cleaning Indicator
Cooling mode(Blue)
Dehumidify mode(Orange)
Note:
1. Display only when in running mode.
2. When unit is running, clean indicator lights, please
clean filter, After cleaned, press reset button on
remote control or press on/off button on unit for 4
seconds to delete the clean indicator lights. The
setting is completed after one beep.
Default indicator
Trouble shooting when environmental temperature indicator failures:
Please check the environmental temperature indicator on PCB
if it's assembled properly and no wires loosen.
Trouble shooting when coil tube temperature indicator failures:
Please check the environmental temperature indicator on PCB
if it's assembled properly and no wires loosen.
EEPROM failure:
After units turns on, it will check EEPROM every 4 minutes. If
continuous failure for 5 times, it will be indicated "failure". When
perform EEPROM checking next time and get normal feedback,
the operation will go back to normal. If not, need to replace PCB.
Water full switch alarm indicator:
Drain the water into a prepared container by the drainage pipe on the
rear panel of the unit. If still doesn't work, please consult a qualified
technician.