Maintenance Display System; Note For Replacement Of Consumable Parts - Sharp AR-5316 Service Manual

Hide thumbs Also See for AR-5316:
Table of Contents

Advertisement

2. Maintenance display system

Toner
Life,
Remaining
a. Press and hold the density adjustment
quantity
LIGHT key for more than 5 sec, and the
check *1
machine will enter the user program
mode.
b. Press and hold the "%" key for more
than 5 sec, and the remaining quantity
will be displayed on the copy quantity
display in one of the following levels:
(Remaining quantity display levels:
100%, 75%, 50%, 25%, 10%, LO)
c. Press the density adjustment LIGHT
key to cancel.
Remaining
NEAR EMPTY
quantity
About 10%
LED
ON
Machine
Operation allowed
Developer
Life
50K
LED
ON at 50K of the
developer count
Machine
Selection is available between Not Stop
and Stop by Service Simulation (SIM 26-
37) Setup.
(If Stop is selected, the LED will flash and
stop at 50K.)
*
*
Maintenance LED
Selection is available among 50K, 25K,
10K, 7.5K, 5K, and free (no lighting) with
SIM 21-1.
*
*
Machine
Not stop
*1: Installation of a new toner cartridge allows to display the remaining
quantity.

3. Note for replacement of consumable parts

A. Toner cartridge
When a waste toner cartridge is removed from the machine, it must be
put in a polyethylene bag to avoid scattering of toner.
B. DV cartridge
Do not shake or put up the developer cartridge. Otherwise developer
may scatter.
16K
EMPTY
Flash
Stop
Default: Not Stop
Clear: SIM 42-1
Default: 50K
Clear: SIM 20-1
AR-5316/5320 MAINTENANCE 10-2
C. DV seal attachment procedure
1) When attaching the DV side Mylar, check the position shown in the
figure below and attach it properly.
2) When attaching the DV side sheet, check the position shown in the
figure below and attach it properly.
(First of all, attach the DV side Mylar.)
*
Be sure to attach the DV side sheet so that the notch is on the
outside.

Advertisement