Download Print this page

Kenwood X34-59 Service Manual page 5

Advertisement

MICROCOMPUTER'S TERMINAL DESCRIPTION
Pin No.
Pin Name
I/O
43
PON CD
O
44
CD LOEJ
I/O CD motor control
45
CD MOTOR
I/O CD motor control
46
VFD CE
O
47
CD DRIVEMUTE O
48
CD CCE
O
49
NC
-
50
CD MRST
O
51~53
NC
-
54
CD MUTE
I
55
CD DISC12 SW
I
56
ROTARY CCW
I
57
ROTARY CW
I
58~61
NC
-
62
VCC2
-
63
NC
-
64
VSS
-
65
NC
-
66
TUN IFC OUT
I
67
PON EXT GND I/O IC2 external input quick charge control
68
MUTE
I/O Mute
69
ANALOG CON
O
70
LX RST
O
71
LX CON
O
72
LX MUTE
I
73
LX REQ M
O
74
NC
-
75
LX REQ S
I
76
PWIC SVR
O
77
PWIC STBY
O
78
PWIC MUTE
O
79
ACC DET
I
80
BU DET
I
81,82
NC
-
83
RDS NOISE
I
Application
CD mechanism power supply control
VFD control request
Motor driver mute output
CD mechanism chip enable
Not used
CD mechanism µ-com reset
Not used
CD mute request
12cm disc detection
VOL key input
VOL key input
Not used
Not used
Not used
Front-end IFC-OUT input
AUX/LX audio switching
Forced reset to slave unit
Start-up request to slave unit
Mute request from slave unit
Communication request to slave unit
Not used
Communication request from slave unit
SVR discharging circuit
Power IC standby control
Power IC mute
ACC power supply detection
Detection of momentary power down
Not used
FM noise detection
X34-59xx-xx
Truth Value
Processing Operation Description
Table
H: Power ON
q
Refer to the truth value table
q
Refer to the truth value table
H: Normal, L: Reset
Output L fi xed
L: Mute request
Pull-up (B.U.)
Detects pulse width
Detects pulse width
Output L fi xed
Output L fi xed
H: Station found, L: No station
L: OFF, Hi-Z: Quick charge, When IC2 is in source select:
Hi-Z, Mute L: L, Momentary power down/Power OFF: L
L: Mute OFF, Hi-Z: Mute ON
AUX: H (Switches after 100ms after fi rst-out mute
begins to work), LX/Other source: L
H: Reset, L: Normal
H: Slave unit ON, L: Slave unit OFF
H: Mute ON, L: Mute OFF
Pull-down (GND)
During 500ms after power OFF and momentary
power down: H, Since then: L
Power ON: H, Power OFF: L
STANDBY source/Momentary power down: L,
TEL mute: L
ACC found: L, No ACC: H
BU found: L, No BU/Momentary power down: H
(Operates after less than 4ms after momentary
power down is detected)
Output L fi xed
Only for model with RDS
5

Advertisement