Start measurement
Adjust RB to the target xy values.
MG3RXXXX
MG3BXXXX
* XXXX indicates the adjusted values between 0000 and 1023
(4 digit decimal number with zero fill).
* G is fixed.
* The default adjustment value of RGB is the parameter value of
Repeat until RGB
the LEV3 command multiplied by 2.
become the target
values.
Adjustment gradation setting (point 2 = 72 gradation adjustment*)
LEV20072
Correction of G value
MG2G0288
When G is changed at gradation 6, calculate the ratio of the
change and set the following value to XXXX: (the value set with
LEV2) x 2 x (the ratio).
Start measurement
Adjust RB to the target xy values.
MG2RXXXX
MG2BXXXX
* XXXX indicates the adjusted values between 0000 and 1023
(4 digit decimal number with zero fill).
* G is fixed.
* The default adjustment value of RGB is the parameter value of
Repeat until RGB
the LEV2 command multiplied by 2.
become the target
values.
Adjustment gradation setting (point 1 = 46 gradation adjustment*)
LEV10046
Correction of G value
MG1G0184
When G is changed at gradation 6, calculate the ratio of the
change and set the following value to XXXX: (the value set with
LEV1) x 2 x (the ratio).
Set
The adjustment value is
reflected in the image.
Adjustment values are set.
OK
Pattern display
Adjustment values are set.
OK
Adjustment values are set.
OK
The adjustment value is
reflected in the image.
Adjustment values are set.
OK
Pattern display
Adjustment values are set.
OK
Adjustment values are set.
OK