Sharp LC-26D43U Service Manual page 21

Hide thumbs Also See for LC-26D43U:
Table of Contents

Advertisement

3.White balance adjustment
Adjustment item
Adjustment conditions
1
Setting
2
Automatic adjust-
[Command]
ment execution
Process mode
KRSW0001
KKT10037
Setting
KYOF0000
OSDS0001
SBSL0016
Multi-point adjustment
MSET0001
Adjustment value
initialization
MSET0004
Point 6
WBI60928
MG6G****
MG6B****
MG6R****
Point 5
WBI50800
MG5G****
MG5B****
MG5R****
Point 4
WBI40480
MG4G****
MG4B****
MG4R****
Point 3
WBI30336
MG3G****
MG3B****
MG3R****
Point 2
WBI20288
MG2G****
MG2B****
MG2R****
Point 1
WBI10184
MG1G****
MG1B****
MG1R****
Writing
MSET0003
Adjustment procedure
For detailed adjustment procedure refer to "Kameyama Model Integral WB Adjustment
Specifications V1.4".
1) Make the following settings for the set.
AV MODE: [DYNAMIC]
Backlight: +16
Aging time: Min. 60 minutes
2) Connect the white balance adjustment tool to the set.
[Adjustment prcedure]
1) Using the remote controller,transmit the "monitor adjustment process" code.
th
2) Set the 6
point to the specified gradation level,With the strongest color being fixed, ,
turn down the R,G and B settings to their reference levels.
th
3) Set the 5
point to the specified gradation level.
Correct the G setting (800 x 6th point G setting /928) (rounded off), and make the R
and B settings to their reference levels.
th
4)
Set the 4
point to the specified gradation level.
Correct the G setting (480 x 6th point G setting /928) (rounded off), and make the R
and B settings to their reference levels.
5)
Set the 3rd point to the specified gradation level.
Correct the G setting (366 x 6th point G setting /928) (rounded off), and make the R
and B settings to their reference levels.
6)
Set the 2nd point to the specified gradation level.
Correct the G setting (288 x 6th point G setting /928) (rounded off), and make the R
and B settings to their reference levels.
st
Set the 1
point to the specified gradation level.
7)
Correct the G setting (184 x 6th point G setting /928) (rounded off), and make the R
and B settings to their reference levels.
8) With the MSET0003 command, write the adjustment values and turn off the AC
power.
* Initial R, G and B settings at point 6: Gradation level set at 928
* Initial R, G and B settings at points 1 thru 5:Correct the setting same remainder of
RGB setting at each point (This is because the adjustment is made to achieve the
same remainder of RGB setting/4 at each point. )
[Adjustment value]
As per the "standard set" submitted by Engineering Department
[LC-26D43U] Teaching Set.
[Adjustment reference] Instrument:[Minolta CA-210] Engineering instrument
Level
Reference
Point 6
928
X=0.272
y=0.277
Point 5
800
X=0.272
y=0.277
Point 4
480
X=0.272
y=0.277
Point 3
366
X=0.272
y=0.277
Point 2
288
X=0.272
y=0.277
Point 1
184
X=0.272
y=0.277
Note
Set conditions for inspection
AV MODE: [DYNAMIC] (Reset)
Monochro: ON
Aging Time: Min. 60 minutes
21
LC-26D43U
Adj. spec
Ins. spec
±0.0012
±0.0020
±0.0012
±0.0020
±0.0012
±0.0020
±0.0012
±0.0020
±0.0020
±0.0030
±0.0035
±0.0045