MD-C2
ICD01 RH-iX0266AW00:FL Driver (iX0266AW) (2/3)
Terminal Name
Pin No.
1
LED-10
P16
2
LED-11
P17
3
LED-12
P30
4
LED-13
P31
5
LED-14
P32
6
LED-15
P33
7
LED-16
P34
8
LED-17
P35
9
LED-18
P36
10
LED-19
P37
11
LED-20
P70
12
RES
RES
13
VOL-DOWN
P74
14
VPL-UP
P75
15
–
VSS1
16
–
CF1
17
–
CF2
18
–
Vdd1
19
KEY0
AN0
20
KEY1
AN1
21
KEY2
AN2
22
KEY3
AN3
23
KEY4
AN4
24
KEY5
AN5
25
JOG-DOWN
AN6
26
JOG-UP
AN7
27
LED-21
P71
28
LED-22
P72
29
REMOTO
P73
30
15G
T0
31
14G
T1
32
13G
T2
33
12G
T3
34
11G
T4
35
11G
T5
36
10G
T6
37
9G
T7
38
8G
T8
39
7G
T9
40
6G
T10
41
5G
T11
42
4G
T12
43
3G
T13
44
2G
T14
45
1G
T15
46
–
VDD3
47*
–
S16
48
P35
S17
49
P34
S18
50
P33
S19
51
–
VP
In this unit, the terminal with asterisk mark (*) is (open) terminal which is not connected to the outside.
Active
Input/Output
Port Name
Level
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Input
Input
Input
–
–
–
–
Input
Input
Input
Input
Input
Input
Input
Input
Output
Output
Input
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
–
Output
Output
Output
Output
–
Setting
in Reset
H
L
REW-LED drive
H
L
STOP-LED drive
H
L
PLAY-LED drive
H
L
FF-LED drive
H
L
MD3-LED drive
H
L
NR2-LED drive
H
L
NR1-LED drive
L
Open drain OFF MD-LED drive
L
Open drain OFF TUNER--LED drive
L
Open drain OFF MD
H
L
CD-DISC-1-LED drive
–
–
Microcomputer reset input
–
Volume use, JOG1-DOWN
–
JOG input, JOG!-UP
–
–
Ground
–
–
4.19MHz
–
–
4.19MHz
–
–
Connection +B
–
STANDBY Operation key input
–
STANDBY Operation key input
–
STANDBY Operation key input
–
STANDBY Operation key input
–
STANDBY Operation key input
–
STANDBY Operation key input
–
"L": input JOG DOWN input
–
"L": input JOG UP input
H
L
CD DISC-2-LED drive
H
L
CD DISC-3-LED drive
–
STANDBY Remote control light reception signal input
–
OFF
Fluorescent grid drive output
–
OFF
Fluorescent grid drive output
–
OFF
Fluorescent grid drive output
–
OFF
Fluorescent grid drive output
–
OFF
Fluorescent grid drive output
–
OFF
Fluorescent grid drive output
–
OFF
Fluorescent grid drive output
–
OFF
Fluorescent grid drive output
–
OFF
Fluorescent grid drive output
–
OFF
Fluorescent grid drive output
–
OFF
Fluorescent grid drive output
–
OFF
Fluorescent grid drive output
–
OFF
Fluorescent grid drive output
–
OFF
Fluorescent grid drive output
–
OFF
Fluorescent grid drive output
–
OFF
Fluorescent grid drive output
–
–
Connection +B
OFF
Not used
–
OFF
Fluorescent grid drive display
–
OFF
Fluorescent grid drive display
–
OFF
Fluorescent grid drive display
–
–
Connection VP
– 80 –
Function