Sharp MD-C2 Service Manual page 23

Table of Contents

Advertisement

5. TEST-PLAY mode
(For comfirmation of the playback ability at the named address.)
Step No.
Setting Method
Step 1
Testmode STOP state
Step 2
Press the X-BASS button.
Step 3
Press once the DISPLAY button. ADRES setting (Target address initial value is indicated)
Press once the MD1 PLAY button.
Step 4
Continuous playback (pit section) (Address + C1 error indication)
Continuous playback (groove section) (Address + C1 error indication)
Step 5
Press once the DISPLAY button. (Address + ADIP error indication)
Continuous playback (groove section)
Step 6
Press once the MD2 PLAY button. TEST-PLAY menu
• If the MD2 PLAY button is pressed while the TEST-PLAY menu is displayed, TEST mode STOP state is set.
• If the MD1 PLAY button is pressed while the TEST-PLAY menu is displayed, continuous playback is started from the current pickup position.
• Whenever the X-BASS button is pressed in the address setting mode, the address changes as follows.
0 0 3 2 → 0 3 C 0 → 0 7 0 0 → 0 8 A 0 → 0 9 5 0 → 0 0 3 2 → ............
• Whenever the DISPLAY button is pressed in the address setting mode, the digit which is changed with -
0 0 3 2 → 0 0 3 2 → 0 0 3 2 → 0 0 3 2 → ............
• The digit of address which has been specified with -
* If the -
/
+ button is held down, the setting changes continuously with 100 ms cycle.
6. TEST-REC mode
With recording mini disk (For confirmation of the playback ability at the named address.)
Step No.
Setting Method
Step 1
Testmode STOP state
Step 2
Press the X-BASS EDIT button.
Step 3
Press once the DISPLAY button. ADRES setting (indication of address initial value)
Step 4
Press once the MD1 PLAY button. While searching, set the search output to "H". To start continuous play,
Step 5
Press once the MD2 PLAY button. TEST-REC menu
• If the MD2 PLAY button is pressed while the TEST-PLAY menu is displayed, TEST mode STOP state is set.
• If the MD1 PLAY button is pressed while the TEST-REC menu is displayed, continuous record is started from the current pickup position.
• Whenever the X-BASS button is pressed in the address setting mode, the address changes as follows.
0 0 3 2 → 0 3 C 0 → 0 7 0 0 → 0 8 A 0 → 0 9 5 0 → 0 0 3 2 → ............
• Whenever the CD STOP button is pressed in the address setting mode, the digit which is changed with -
0 0 3 2 → 0 0 3 2 → 0 0 3 2 → 0 0 3 2 → ............
• The digit of address which has been specified with -
* If the -
/
+ button is held down, the setting changes continuously with 100 ms cycle.
• Be sure to remove since excessive raising results in breakage of the pickup.
7. INNER mode
Step No.
Setting Method
Step 1
Testmode STOP state
Step 2
Press the EQUALIZER button.
Step 3
Press once the MD1 PLAY button. INNER switch position measurement
Step 4
Press once the MD2 PLAY button. INNER menu
: Address
Remarks
The AUTO preliminary adjustment should have been completed.
TEST-PLAY menu
/
+ and DISPLAY button in the address setting mode is set to +01H/-01H.(0~F)
Remarks
The AUTO preliminary adjustment should have been completed.
TEST-REC menu
return it to "L".
Continuous recording
/
+ and CD STOP button in the address setting mode is set to +01H/-01H.(0~F)
Remarks
INNER menu
(SUBQ address and C1 error are also indicated.)
– 23 –
MD-C2
Display
[ t s m
e
]
[ T E S T _ P L A Y _ ]
[ A D R E S _ 0 0 3 2 ]
[s
c
]
[a
c
]
[a
a
]
[ T E S T _ P L A Y _ ]
/
+ changes as follows.
Display
[ t s m
e
]
[ T E S T _ R E C _ _ ]
[ a 0 0 3 2 _ p w
]
[ a
p w
]
[ T E S T _ R E C _ _ ]
/
+ changes as follows.
Display
[ t s m
e
]
[ _ _ I N N E R _ _ ]
[s
c
]
[ _ _ I N N E R _ _ ]

Hide quick links:

Advertisement

Table of Contents