b.
Record File
Choose one of the format, AVI or JPEG .
c.
Record Time Setting
Set up the video recording time for Pre Alarm and Post Alarm when
motion is detected, I/O, or other devices is triggered.
Note: Pre/Post Alarm record time is base on record time setting and
restricted to IP Cam built-in Ram memory. If the quantity of data is too huge
or video quality too high, recording frame might drop or decrease on post
alarm recording time.
d.
Network Dis-connected
To avoid video loss, the camera will start to save the video to Micro
SD card when it detect no network connection. The video recording will
continuously be saved into Micro SD card and divided into every 10
minutes a file until the network is reconnected successfully. The oldest file
will be deleted if the capacity of Micro SD card is full.
This function is only enabled under wire connection.
e.
Network IP check:
Key in the target IP address and interval. The camera checks once in
a while according to the setting interval time that if itself can linked to the
target IP address. If connection failed, the camera starts to save the video
to Micro SD card.