Yanmar 3JH5E Operation Manual page 37

Hide thumbs Also See for 3JH5E:
Table of Contents

Advertisement

12/05
Alarms
Checking the Warning Devices
Before and after engine start, make sure that the instruments and warning devices
operate correctly.
If the engine runs out of coolant or lubricating oil and the instruments and warning devices
fail, they can not give you warning to prevent accidents. This can also lead to incorrect
operation and cause further malfunctions of the engine.
Before Engine Start
1. Turn on the battery switch.
2. Push the power switch on.
• All alarm lamps light up for 4 seconds.
• After 4 seconds, the charge lamp and the lubricating oil pressure alarm lamp light up,
and the hourmeter is displayed.
• The alarm buzzer sounds until the engine starts.
After Engine Start
After engine start, make sure that the warning devices operate correctly and according to
"After start" in the below table.
• All alarm lamps turn off. The above check tells you whether the electric circuit for the
alarm lamps and alarm buzzer operate correctly. If they do not operate correctly,
inspection and repair are required. Consult your dealer or distributor for repairs.
Correct operation of the warning devices
Instrument panel (power switch)
Starter switch
Alarm buzzer
Charge lamp
Coolant temperature lamp
Engine lubricating oil pressure lamp
LCD display
JH Series Operation Manual
Immediately
After 2 seconds
Before start
OFF
ON
ON
ON
ON
ON
ON
ON
Yanmar
Full display
PRODUCT OVERVIEW
Power ON
After 4 seconds
ON
OFF
ON
Hourmeter
After start
ON
OFF
OFF
OFF
OFF
29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

4jh4-hte14jh4-hte4jh5e4jh4-te

Table of Contents