B. Rebuilding an Array
Rebuilding is the process of restoring data to a hard drive from other drives in the array. Rebuilding applies only
to fault-tolerant arrays such as RAID 1, RAID 5 or RAID 10 arrays. The procedures below assume a new drive
is added to replace a failed drive to rebuild a RAID 1 array. (Note: The new drive must have equal or greater
capacity than the old one.)
Turn off your computer and replace the failed hard drive with a new one. Restart your computer.
• Enabling Automatic Rebuild
Step 1:
When the message "Press <Ctrl-I> to enter Configuration Utility" appears, press <Ctrl> + <I> to enter the RAID
Configuration Utility. The following screen appears after you enter the RAID Configuration Utility.
1. Create RAID Volume
2. Delete RAID Volume
"Degraded volume and disk available for rebuilding detected. Selecting
a disk initiates a rebuild. Rebuild completes in the operating system.
Select the port of the destination disk for rebuilding (ESC to exit):
RAID Volumes :
ID
Drive Model
None defined.
5
Hitachi HDS721050CLA
Physical Disks :
ID
Drive Model
4
Hitachi HDS72105
5
Hitachi HDS72105
[ hi ]-Select
Step 2:
Select the new hard drive to add into the array to be rebuilt and press <Enter>. The following screen appears,
indicating that an automatic rebuild will be performed after you enter the operating system. If you do not enable
automatic rebuild on this stage, you have to manually rebuild the array in the operating system (see the next
page for more details).
1. Create RAID Volume
2. Delete RAID Volume
3. Reset Disks to Non-RAID
RAID Volumes :
ID
Name
0
Volume0
Physical Devices :
ID
Devices Model
4
Hitachi HDS72105
5
Hitachi HDS72105
[ hi ]-Select
Configuring a RAID Set
Intel(R) Rapid Storage Technology - Option ROM - 14.0.0.2209
Copyright (C) Intel Corporation. All Rights Reserved.
[
DEGRADED VOLUME DETECTED
[ DISK/VOLUME INFORMATION ]
[ hi ]-Previous/Next
Serial #
JP1532ER04EJTK
JP1532FR046M2K
Intel(R) Rapid Storage Technology - Option ROM - 14.0.0.2209
Copyright (C) Intel Corporation. All Rights Reserved.
[ DISK/VOLUME INFORMATION ]
Level
RAID1(Mirror)
Serial #
JP1532ER04EJTK
JP1532FR046M2K
Volumes with "Rebuild" status will be rebuilt within the operating system.
[ MAIN MENU ]
Serial #
JP1532FR046M2K
[ENTER]-Select
Size
465.7GB
465.7GB
[ESC]-Exit
[ MAIN MENU ]
Strip
Size
N/A
465.7GB
Size
465.7GB
465.7GB
[ESC]-Exit
- 80 -
]
3. Reset Disks to Non-RAID
4. Exit
Size
465.7GB
[ESC]-Exit
Type/Status(Vol ID)
Member Disk (0)
Non-RAID Disk
[ENTER]-Select Menu
4. Recovery Volume Options
5. Acceleration Options
6. Exit
Status
Bootable
Rebuild
Yes
Type/Status(Vol ID)
Member Disk (0)
Non-RAID Disk
[ENTER]-Select Menu