HP 6033A series Service Manual page 22

Autoranging system dc power supply
Table of Contents

Advertisement

i.
Run the program listed in step e. The value displayed by the controller should be the value noted in step h:
± 0.02Vdc (6033A).
± 0.092Vdc (6038A).
Load Effect (Load Regulation). Constant-voltage load effect is the change in dc output voltage (Eo) resulting from a
load-resistance change from open-circuit to full-load. Full-load is the resistance which draws the maximum rated output
current at voltage Eo. Proceed as follows:
a.
Connect the test equipment as shown in Figure 2-5. Operate the load in constant resistance mode (Amps/Volt) and set
resistance to maximum.
b.
Turn the unit's power on, and, using DISPLAY SETTINGS pushbutton switch, turn up current setting to full output.
c.
Turn up output voltage to:
7.0Vdc (6033A).
20.0Vdc (6038A).
as read on the digital voltmeter.
d.
Reduce the resistance of the load to draw an output current of:
29Adc (6033A).
10 Adc (6038A).
Check that the unit's CV LED remains lighted.
e.
Open-circuit the load.
f.
Record the output voltage at the digital voltmeter.
g.
Reconnect the load.
h.
When the reading settles, record the output voltage again. Check that the two recorded readings differ no more than:
± 0.0027Vdc (6033A).
± 0.005Vdc (6038A).
Source Effect (Line Regulation). Source effect is the change in dc output voltage resulting from a change in ac input
voltage from the minimum to the maximum value as specified in Input Power Requirements in the Specifications Table, in
the Operating Manual. Proceed as follows:
22
Figure 2-5. Basic Test Setup

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

6038a series