HP 6033A series Service Manual page 13

Autoranging system dc power supply
Table of Contents

Advertisement

Printed Circuit
Board
A1 Main Board
A1 Main Board
A4 Power Mesh Board
A4 Power Mesh Board
A2 Control Board
A2 Control Board
A2 Control Board
A2 Control Board
A2 Control Board
A8 HP-IB Board
A8 HP-IB Board
A8 HP-IB Board
Table 2-2. Guide to Recalibration After Repair
Block Name
Constant Voltage Circuit
(All Except Current Source)
Constant Voltage Circuit
(Current Source)
Constant Current Circuit
Power Limit Comparator
Bias Power Supplies
( + & -15V Supplies)
Voltage Monitor Buffer
Analog Multiplexer
Readback DAC
Ref.
Perform These Procedures
Desig.
R3
Current Monitor Full Scale Calibration
Constant Current Full Scale Calibration
T1
Power Limit Calibration
T3
Power Limit Calibration
CR7
Power Limit Calibration
All
Voltage Monitor Zero Calibration
Common Mode Calibration
Remote Readback Zero Calibration
Constant Voltage Full Scale Calibration
Voltage Monitor and Remote Readback Full
Scale Calibration
Constant Voltage Zero Calibration
All
Resistance Programming Full Scale Calibration
All
Current Monitor Zero Calibration
Constant Current Zero Calibration
Current Monitor Full Scale Calibration
Constant Current Full Scale Calibration
All
Power Limit Calibration
All
All Calibration Procedures
All
Voltage Monitor Zero Calibration
Remote Readback Zero Calibration
Constant Voltage Full Scale Calibration
Voltage Monitor and Remote Readback Full
Scale Calibration
Constant Voltage Zero Calibration
All
Remote Readback Zero Calibration
Constant Voltage Full Scale Calibration
Voltage Monitor and Remote Readback Full
Scale Calibration
Constant Voltage Zero Calibration
All
Remote Readback Zero Calibration
Constant Voltage Full Scale Calibration
Voltage Monitor and Remote Readback Full
Scale Calibration
Constant Voltage Zero Calibration
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

6038a series

Table of Contents