9. B-Y POSITIVE GAIN (indoor)
1) Camera mode & 3100˚ K color bar chart
2) Connect a video output terminal to a vec-
torscope and a TV.
3) Press the FF(Mode Up)/REW(Mode Down)
button so that OSD shows "174XX XX".
4) Ensure that camera picks up image on 3100˚ K
color bar chart precisely and the illumination is
1500-2000 Lux.
5) Press the PLAY (Data Up)/STOP (Data Down)
so that the blue level is 40IRE.
6) Press the START/STOP (Confirm) button to
store data.
7) The OSD shows "OK" after finishing the
adjustment.
9-b. B-Y POSITIVE GAIN (outdoor)
1) Camera mode & 5100˚ K color bar chart
(3100°K color bar chart + C16 filter)
2) Connect a video output terminal to a vec-
torscope and a TV.
3) Press the FF(Mode Up)/REW(Mode Down)
button so that OSD shows "O88 XX XX".
4) Ensure that camera picks up image on 5100˚ K
color bar chart precisely and the illumination is
1500-2000 Lux.
5) Press the PLAY (Data Up)/STOP (Data Down)
so that the blue level is 30IRE.
6) Press the START/STOP (Confirm) button to
store data.
7) The OSD shows "OK" after finishing the
adjustment.
Samsung Electronics
10. B-Y NEGATIVE GAIN (indoor)
1) Camera mode & 3100˚ K color bar chart
2) Connect a video output terminal to a vec-
torscope and a TV.
3) Press the FF(Mode Up)/REW(Mode Down)
button so that OSD shows "175 XX XX".
4) Ensure that camera picks up image on 3100˚ K
color bar chart precisely and the illumination is
1500-2000 Lux.
5) Press the PLAY (Data Up)/STOP (Data Down)
so that the yellow level is 50IRE.
40IRE
6) Press the START/STOP (Confirm) button to
store data.
7) The OSD shows "OK" after finishing the
adjustment.