Installation (Outdoor)
VENTILATION
OUTDOOR INSTALLATION ONLY
For outdoor installation with built in vent, the heater must be placed in a suitable area on a level, noncombustible
surface. Do not install the heater under an overhang with clearances less than 3 feet from the top of the heater. The
area under an overhang must be open on three sides.
In an outdoor installation it is important to ensure water is diverted from overhanging eves with a
proper gutter/drainage system. The heater must be set on a level foundation for proper drainage.
Under certain conditions, "heavy rains or unusually high winds", it may be necessary to install an
outdoors vent. In this situation, use vent adaptor P/N 460507 and outdoor vent P/N 471357.
This unit shall not be operated outdoors at temperatures below -20
OUTDOOR INSTALLATION
VENTING GUIDELINES
Walkway
Figure 17.
If installing the heater next to or near an air conditioning unit or a heat pump, allow a minimum of 24 in.
between the air conditioning unit and the heater.
P/N 472235
(Outdoor Shelter Installation in Canada,
IMPORTANT!
IMPORTANT!
NOTE
A
C
4'
Vent Termination:
Must be at least 3 ft. above any forced
A
air inlet located within a 10 ft. radius.
Must be located 4 feet away from the building wall,
and at the following distances away from any door,
window, or gravity air inlet:
B
4 ft. below, or
4 ft. horizontally, or
C
Check local building codes for setback requirements.