Hitachi EP-A3000 Instruction Manual

Hitachi EP-A3000 Instruction Manual

Air purifier
Hide thumbs Also See for EP-A3000:
Table of Contents

Advertisement

Thank you for purchasing a Hitachi air
This air purifi er is for home use only. Do
not use it for any other purpose than air
purifying.
Please read this instruction manual
carefully before use to ensure proper
operation of the unit.
Keep this manual for future reference in
an easily accessible place.
Read the "Safety Precautions"
to ensure proper use.
Contents
Before Use
Features / Name of Each Component / Operation
Buttons and Indicators / Accessories · · · · · · · ·
Safety Precautions · · · · · · · · · · · · · · · · · · ·
Cautions on Use · · · · · · · · · · · · · · · · · · · · ·
Preparations for Operation · · · · · · · · · · · · ·
·
·
Installation · · · · · · · · · · · · · · · · · · · · · · · · · ·
Operating Air Purifi er
Using Remote Controller · · · · · · · · · · · · · · ·
·
·
·
·
·
Using the Control on Purifi er · · · · · · · · · · · ·
· Memory Function · Odor Sensor · Auto Detection

Cleaning and Maintenance

Cleaning · · · · · · · · · · · · · · · · · · · · · · · · · · ·
·
Filter Replacement · · · · · · · · · · · · · · · · · · ·
·
·
Troubleshooting Guide · · · · · · · · · · · · · · · ·
Replacement Parts · · · · · · · · · · · · · · · · · · ·
Specifi cations · · · · · · · · · · · · · · · · · · · · · · ·
P.E-4-E-5
Instruction
Manual
Hitachi Air Purifi er
Model
EP-A3000
· · · · · · · · · · · · · · · · · ·
· · · · · · · · · · · · · · · · · · · · ·
· · · · · · · · · · · · · · · · · · ·
· · · · · · · · · · · · · · · · · ·
· · · · · · · · · · · · · · · · · · · · · · ·
· · · · · · · · · · · · · · · · · · · · · · · · ·
·
· · · · · · · · · · · · · · · · ·
Replacement Interval · Precautions on Filter Handling
· · · · · · · · · · · · · · · · · · · · ·
Desktop type
E-2
E-4
E-6
E-7
E-7
· · · · · ·
E-7
E-7
E-8
E-8
E-9
E-9
E-10
E-10
E-11
E-11
· · ·
E-11
E-12
E-12
E-13
· · · ·
E-13
E-13
E-14
E-14
E-15

Advertisement

Table of Contents
loading

Summary of Contents for Hitachi EP-A3000

  • Page 1: Table Of Contents

    · · · · · · · · · · · · · · · · · · · · · · · · · Using Timer E-10 Thank you for purchasing a Hitachi air Using the Control on Purifi er · · · · · · · · · · · · E-11 purifi...
  • Page 2: Purifi Er

    Features / Name of Each Component / Accessories Filter assembly Pre-filter (Allergen-free, catechin deodorizing filter) Removes large size dust. White surface: Dust filter Black surface: Deodorizing filter Air inlet Indicator section P.E-3 Purifier Panel Remote controller pocket Hand grip Air outlet Power plug Power cord...
  • Page 3: Remote Controller

    Operation Buttons and Indicators / P.E-OO shows a page with further description. Operation Buttons and Indicators On/Off Button P.E-11 Auto Mode P.E-9 Airflow Level P.E-9 Indicates airflow rate during operation. The indicator is lit green when Use this button to start and stop operation, and to switch the the Auto Mode is running.
  • Page 4: Safety Precautions

    Safety Precautions Please read the following safety precautions carefully before using the air purifi er. To prevent injury to the user or other people and property damage, the following instructions must be followed. Also read the precautions appearing in the text carefully to ensure proper use. Definition of each indication Incorrect operation due to ignoring instruction will cause harm or damage.
  • Page 5 Otherwise, it may cause carbon monoxide poisoning. Use dry cell batteries properly after reading the precautions on them. Use a genuine fi lter for the Hitachi Air Purifi er. Other fi lters may cause unit failure. The appliance is not to be used by children or persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction.
  • Page 6: Cautions On Use

    Cautions on Use Do not install the air purifier in an Do not block the air inlet or air outlet. unstable place, near any obstacles or Blocking them may cause unit failure. on a floor. Such installation may cause the air purifier to topple over or fall.
  • Page 7: Preparations For Operation

    Preparations for Operation Lay a soft cloth or the like beneath the purifi er to protect the fl oor against scratch. Note No cleaning effect is obtainable if the fi lter is installed with plastic bag. It may also be a cause of malfunction. Setting Filter in Purifier (Perform the same procedure when replacing filter.) Remove the panel.
  • Page 8: Using Remote Controller

    Using Remote Controller Here we describe how to operate the air purifier using the remote controller. For the operation using the control on the purifier, please refer to P.E-11 . Starting Operation Remote Controller Air Purifier Indicator Section Securely insert the power plug into In the first 3 minutes after the power cord is plugged in, the unit checks the room air condition and saves it AC outlet.
  • Page 9: Selecting Auto Mode

    Selecting Auto Mode (Basics) 3 Auto modes are available for your choice. The fan will not stop during operation in the Auto Mode. Auto Modes and Tips for Selection Mode Tips for Selection This is a normal operation mode. Air Purify The odor sensor detects the degree of air contamination, and airflow rate is switched automatically.
  • Page 10: Max Operation

    Using Remote Controller (Continued) Max Operation This operation is useful when many people smoke or when you want quick cleaning of room air. The airflow indicator blinks for 5 minutes. Press button. Blinking green The operation with Max airflow will continue for about 5 minutes.
  • Page 11: Using The Control On Purifi Er

    Using the Control on Purifier Press button. Operation starts. Every time you press the button to stop the unit, the lit indicator switches in the order shown below until stopping the unit. Odor Pollen Purify Memory Function / Sensors / Auto Detection Memory Function (Only with the remote controller) When you stop the operation and then restart, the purifier will resume the operation status before shutdown.
  • Page 12: Cleaning

    Cleaning (Guide for cleaning: Once a month) Do not splash water on the purifier body. Water splash can be a cause of failure. Note Do not use a volatile solvent, such as gasoline, thinner, benzene, wax, kerosene, alcohol, etc. or polishing powder, or alkaline cleaner.
  • Page 13: Filter Replacement

    Filter Replacement Replacement Interval The filter is a consumable part. For the filter replacement interval, use approx. 2 years as a guide when the air purifier processes the smoke generated by 5 cigarettes smoking a day. The dust filter should be replaced early if its color shows the resemblance to the color on the dirtiness label attached to the purifier body.
  • Page 14: Troubleshooting Guide

    Troubleshooting Guide Before asking for repair check the following once again Symptom Check to see Solution Is power plug securely inserted into Securely insert the power plug into AC No air blows out outlet. AC outlet? or power does not Switch on breaker.
  • Page 15: Specifications

    Specifications Model EP-A3000 Power supply AC220 50/60Hz AC240 50/60Hz Airfl ow switching Medium Silent Medium Silent Power consumption (W) 37/43 21/20 18/16 37/43 25/24 22/20 Airfl ow rate (m /min) 2.8/3.2 1.4/1.1 0.9/0.6 2.8/3.2 1.7/1.4 1.2/0.8 Applicable fl oor space...

Table of Contents