7.4 Alarms
Alarm
Er 01
Er 02
Er 03
Er 04
Er 05
Er 07
Er 08
Er 09
Er 10
Er 11
Er 12
Er 15
Er 16
Er 17
Er 18
Er 23
Er 25
Er 26
Er 27
Er 34
Er 35
Er 39
Er 41
Er 42
Other messages:
Sond
Service
Clean
Ignition Block
Er 20
Door
Er 06
Link Error
Description
Safety Thermostat HV 1
Safety Pressure Switch HV 2
Shutting down due to the low temperature of exhaust gases / high
temperature in the hoper
Shutting down due to too high water temperature
Shutting down due to too high temperature of exhaust gases
Encoder error
Encoder error. This error may occur due to the setting of round numbers.
High water pressure
Low water pressure
Clock error in the real time
Shutting down due to the failed ignition
Lack of electricity
Communication error RS485
Error in the air flow regulator
Lack of pellets
Active probe of the boiler, buffer or return line
Faulty motor for burner cleaning
Faulty motor for cleaning
Faulty motor for cleaning 2
Vacum is below the minimum
Vacum is above the maximum
Faulty sensor of the air flow regulator
The minimum air flow in the Check-up phase has not been reached
The maximum air flow has been reached (F40)
Visualisation of the condition of temperature probes
Notification that the defined period for product servicing has expired
Notification that it is time to clean the product
This message will appear if the system has been shut down in the ignition
period by en external device: the system stops when enters operation phase
Grid sensor open
Open door
Pellet thermostat active
Error in communication between the motherboard and display