  • Page 2: Table Of Contents

    6.Installation ..................6 7.Function Operations ................8 8. User Menu ..................10 9.Maintenance and Cleaning ..............12 10. Environmental Protection ............. 15 11. Appendix ..................16 ABC PROIZVOD D.O.O. Miloša Obrenovića 2 31000 Užice telefoni: +381 (0)31 514 501. 514 502 e-mail: office@abcproizvod.rs...
  • Page 3: Overview Of Stove Parts

    1. OVERVIEW OF STOVE PARTS...
  • Page 4 1.1 Description of Stove Parts DESCRIPTION Firebox sheets Interior firebox sheets Pedestal Pellet inserter Encased spiral Air injection device Assembly of sheets behind the firebox Hoper Top firebox outlet Bottom firebox outlet Top burner outlet Top outlet Ribbed outlet Stove door Burner holder Burner Front vermiculite plate “left”...
  • Page 5: Technical Characteristics

    2.TECHNICAL CHARACTERISTICS Characteristics Value Efficiency ratio (%) 90,1 Weight (kg) Height (mm) 1080 Width (mm) Depth (mm) Min-max stove power (kW) 2,4 - 9 Required draught (Pa) Hoper capacity (kg) Operation autonomy (max-min) 50h - 13h Pellet Characteristics Thermal power (kWh/kg) 4,5 - 5 Length (mm) 10 - 30...
  • Page 6: Important Information

    3.IMPORTANT INFORMATION General Warnings and Safety Information § Read the entire manual before putting the stove into operation. § Only adequate means of transportation with the confirmed load capacity may be used to transport the product. § Fuel combustion results in extensive heating of the external stove surfaces (door, glass, side walls, flue pipe, etc.).
  • Page 7: Pellet Specification

    4.PELLET SPECIFICATIONS What is pellet? The wooden pellet is standardized fuel. Every manufacturer must comply with certain rules in order to provide highly energy efficient heating. Please check with your local dealer for the list of manufacturers of attested pellets. The use of poor quality pellets may have a negative impact on the stove operation.
  • Page 8: Technology

    Storage of Pellets It is very important that the pellets are stored at the dry place. It is not advisable to store pellets in bags exposed to atmospheric conditions. Too wet pellets may block the auger 5.TECHNOLOGY Your new stove is technologically enhanced as a result of years of testing and top quality built-in components.
  • Page 9 6.1 Electrical Connection § The stove is equipped with the power supply cable that needs to be connected to the mains 230V/50Hz § The average power consumption is ± 20W during operation and 300 W in the ignition phase for about 10 minutes. §...
  • Page 10: Function Operations

    7.FUNCTION OPERATIONS 7.1 Control Panel: Functions and Use CHRONO DATE AND TIME ALARM L1 L2 L3 L10 L11 PELLET POWER Buttons Led lampice Buttons Function Light Function ON-OFF / alarm reset / exit from the Heater on menu Menu / data storage / chrono option Motor reducer on activation Visualisation / increased parameter...
  • Page 11 7.2 Alarms System Alarm DESCRIPTION condition Number Safety thermostat Blocked Er 01 Safety Pressure Switch Blocked Er 02 Shutting down due to the low temperature of exhaust gases Blocked Er 03 Shutting down due to the high temperature of exhaust gases Blocked Er 05 Pellet safety thermostat...
  • Page 12: User Menu

    8. USER MENU 8.1 Setting pellet power The pellet power may be set in this menu. The mode may be manual or automatic. In the first case the user shall select the pellet power, while in the second case the system automatically selects the pellet power based on the set temperature.
  • Page 13 Midnight time settings: Set the ON time of the previous day at the desired time (for example, 20.30) Set the OFF time of the previous day at 23.59 Set the ON time for the next day at 00.00 Set the OFF time for the next day (for example, 6.30) The system will be ON on Thursday at 20.30 and OFF on Wednesday at 6.30.
  • Page 14: Maintenance And Cleaning

    8.7 Language Settings In order to activate this function the stove must be off. This function is used to change the software language. The language that is bolded is in use. 8.8 Instalers menu The access to this menu is only allowed to authorised service centres and installers and is password protected.
  • Page 15 9.2 Burner cleaning Clean the burner (Part No. 16 on the list of parts) on a daily basis. Make sure that the air intakes are always clean. The burner may be easily cleaned inside the stove. The burner holder (Part No. 15 on the list of parts) shall be vacuum cleaned.
  • Page 16 Figure No. 2 Figure No. 3 Figure No. 4 9.5 Cleaning of the fan case The fan case shall be cleaned twice a year or after having spent about 700kg of pellets. The fan is located in the bottom part of the stove under the hopper. 1.
  • Page 17: Environmental Protection

    10. ENVIRONMENTAL PROTECTION The crossed-out trash can indicates that this product cannot be treated as household waste. Instead, the product shall be handed over to designated collection centres for the recycling of secondary raw materials. The adequate storage of this product will prevent the potential adverse impacts on environment and health of people which could otherwise be caused by inappropriate waste handling of this product.
  • Page 18: Appendix

    (Construction Products Directive) 89/ 106/ EEC as well as the following harmonized standard: EN 14785 In 2007, ABC PROIZVOD doo, Užice implemented the quality management system SRPS ISO 9001/ 2008, which is maintained and improved. Another 2 standards have been implemented since 2013:...