Alarm Recording; Alarm Recording Connection; External Time Clock Adjustment - Mitsubishi HS-S8300E(BRS) Installation And Operation Manual

Time lapse video cassette recorder
Table of Contents

Advertisement

ALARM RECORDING

It is possible to switch from all recording modes to the 3H - L24H recording mode by applying an alarm signal to
the SET IN terminal on the rear panel.
ALARM SET INPUT
3H - 960H, 0H
RECORDING
NORMAL mode
• Set the alarm recording mode and alarm recording period with the "RECORDING SET UP" menu. (See page 10.)
• The index signal is automatically recorded when an alarm recording begins. (INDEX indicator flashes on the fluorescent display.)
• To record the index signal, the first 15 seconds of the alarm recording are in 3H mode.
• While the index signal is being recorded (for 15 seconds), if another set signal is applied to the SET IN terminal, it will not trigger a
new alarm recording.
Alarm set
switch
MIC
SET
RST
IN
If the "ALARM REC DURATION" of the "RECORDING SET UP" menu is set to other than "MAN1", the on-screen clock can be reset to
the nearest hour, by applying a signal to the RST (RESET) IN terminal. For example, if the current time is 11:29:59, it will be reset to
11:00:00; and if the current time is 11:30:00, it will be reset to 12:00:00.
*1: When connecting the MODE terminal of the 1st VCR with RST (RESET) IN terminal of the 2nd VCR and if the "MODE OUT" of the
"REAR TERMINAL" menu is set to "CLOCK ADJ", the on-screen clock of the 2nd VCR will automatically be adjusted to that of the 1st
VCR.
3H
3H - 960H, 0H
3H - L24H
RECORD-
RECORDING
RECORDING
ING
15sec
ALARM mode
NORMAL mode

ALARM RECORDING CONNECTION

External alarm lamp
or buzzer
SET
RST
REC GND ALM MODE
CLK CALL
IN
OUT
IN
OUT
AUDIO
IN
OUT
VIDEO
Alarm reset switch

EXTERNAL TIME CLOCK ADJUSTMENT

REC GND ALM MODE
CLK
CALL
OUT
1st VCR
• It is possible to switch to the alarm recording by ap-
plying the set signal from the alarm sensor during re-
cording in 3H,L12H, L24H, 48H - 960H or 0H mode.
RESET
IN
OUT
S-VIDEO
REMOTE
*1
SET
RST
REC GND ALM MODE
IN
OUT
22
The alarm can be confirmed from a distance by
connecting the ALM (ALARM) OUT terminal to
an existing alarm system panel or other external
devices such as a buzzer.
CLK
CALL
2nd VCR

Advertisement

Table of Contents
loading

Table of Contents