Service Call
Toner sensor detected error. 1) Is an Error message displayed?
160: Y Toner
161: M Toner
162: C Toner
163: K Toner
Service Call
Thermistor Slope Error
167: Error
Service Call
Compensation Thermistor
168: Error
Error
Service Call
Upper Side Thermistor Error 1) Is an Error message displayed?
169: Error
Service Call
Fuser Thermistor short-
170: Error
circuit or Open is detected
171: Error
(High Temperature (HOT) or
174: Error
Low Temperature (COLD))
175: Error
Service Call
Thermistor indicates High
172: Error
Temperature (HOT) Error.
176: Error
Service Call
Thermistor indicates Low
173: Error
Temperature (COLD) Error.
177: Error
Service Call
Wrong Fuser Standard
179: Error
Service Call
The engine detects com-
180: Error
munication is not possible
to
with the optional unit.
186: Error
180:Envelope Feeder
(Unused)
181:Duplex unit
182:Tray2 unit
183:Tray3 unit
184:Tray4 unit
185:Tray5 unit
186:Finisher unit
Service Call
Communication with control
187: Error
panel failed.
Service Call
Sub-CPU I/F Error
188: Error
Service Call
Inverter Unit I/F Error
189: Error
Service Call
System Memory Overflow
190: Error
Service Call
PU Firm Download Error
200: Error
to
202: Error
Power
Custom Media Table
On/off209:
Download Error
DOWNLOAD
ERROR
44043511TH Rev.2
Table 7-1-1 Operator Alarm (4/9)
Cause
Error Description and Analysis
2) Does the Error take place again?
1) Is an Error message displayed?
2) Does the Error take place again?
1) Is an Error message displayed?
2) Does the Error take place again?
2) Does the Error take place again?
1) Is an Error message displayed?
2) Does the Error take place again?
1) Is an Error message displayed?
2) Does the Error take place again?
1) Is an Error message displayed?
2) Does the Error take place again?
1) Is the model and power voltage of
the fuser mounted proper?
2) Fuser is properly mounted, but
Error results again.
1) Is an Error message displayed?
2) Does the Error take place again?
Is the control panel and cable
connected properly?
Sub-CPU Communication Error
1) Inverter communications error
2) Does the Error take place again?
System Memory Overflow
Error occurred when downloading PU
firmware.
Failed to download custom media
table.
Oki Data CONFIDENTIAL
Remedy
Judgement
Yes
Replace toner sensor or Assy
(SGG-PCB).
Yes
Replace toner sensor or Assy
(SGG-PCB).
Yes
Turn ON power again.
Yes
Leave in that state for 30 minutes
then turn ON power again.
Yes
Turn ON power again.
Yes
Leave in that state for 30 minutes
then turn ON power again.
Yes
Turn ON power again.
Yes
Leave in that state for 30 minutes
then turn ON power again.
Yes
Turn ON power again.
Yes
Leave in that state for 30 minutes
then turn ON power again.
Yes
Turn ON power again.
Yes
Leave in that state for 30 minutes
then turn ON power again.
Yes
Turn ON power again.
Yes
Leave in that state for 30 minutes
then turn ON power again.
No
Assemble the proper fuser.
Yes
Check to see that the fuser is
properly assemble.
Yes
Replace fuser.
Yes
Turn ON power again.
Yes
Replace optional unit.
No
Connect properly
Yes
Replace the control panel and
cable.
Check the connection of the S2P
board.
Replace the S2P board.
Yes
Check the connection of the I/F
cable.
Yes
Replace the V72-13 board.
Power OFF/ON
Replace CU PCB. (Replace
EEPROM)
After turning ON the power again,
try downloading again.
(This process isn't executed for
regular operations, therefore, will
not occur)
After turning ON the power again,
try downloading again.
(This process isn't executed for
regular operations, therefore, will
not occur)