4.

Command list

4.1 Operation commands

while the splash screen is being displayed, the splash screen is only canceled.)
The operation commands are used for the basic operation setting of this projector. They may not be executed
while the signals are changed. The operation commands have no data codes.
ITEM
POWER ON
POWER OFF
INPUT COMPUTER 1
INPUT COMPUTER 2
INPUT DVI
INPUT VIDEO
INPUT S-VIDEO
[Example]
When setting the input signal to COMPUTER 1. (Figures and symbols enclosed in quotation marks
are ASCII codes.):
Sending commands
from the PC, etc.
'30' '30' '5F' '72' '31' '0D'
00_r1
4.2 Reading command diagram
The projectors operating status, such as POWER-ON/OFF and the currently selected input terminal, etc. can be
monitored.
ITEM
POWER ON
POWER OFF
INPUT COMPUTER 1
INPUT COMPUTER 2
INPUT DVI
INPUT VIDEO
INPUT S-VIDEO
POWER ON/OFF IMPOSSIBLE
POWER ON/OFF POSSIBLE
NO SIGNAL SUPPLIED
SIGNAL SUPPLIED
Use the following commands to obtain the values of the items in the INFORMATION menu.
ITEM
LAMP TIME (LOW)
RESOLUTION
VERTICAL FREQUENCY
HORIZONTAL FREQUENCY
SYNC. TYPE
"hhhh" and "mm" represent hours and minutes respectively.
"HHHH" and "VVVV" represent the horizontal and vertical resolutions respectively.
Use the following commands to obtain other information.
ITEM
Model name
Serial number
Input source
(Not executable in stand-by mode. When the commands for input select are sent
Function
Character
ASCII
!
21h
"
22h
_r1
5Fh 72h 31h
_r2
5Fh 72h 32h
_d1
5Fh 64h 31h
_v1
5Fh 76h 31h
_v2
5Fh 76h 32h
'30' '30' '5F' '72' '31' '0D'
00_r1
Character
Function
vP
vP
vI
vI
vI
vI
vI
vPK
vPK
vSM
vSM
Function
Character
vLE
76h 4Ch 45h
vRESO
76h 52h 45h 53h 4Fh
vVFREQ
76h 56h 46h 52h 45h 51h
vHFREQ
76h 48h 46h 52h 45h 51h
vSYNCT
76h 53h 59h 4Eh 43h 54h
Function
Character
vMDL
76h 4Dh 44h 4Ch
vS/N
76h 53h 2Fh 4Eh
vSOUCE
76h 53h 4Fh 55h 43h 45h
This command is invalid for 1 minute after the power is turned off.
This command is invalid for 1 minute after the power is turned on.
This command will not be executed in Stand-by mode or when the MUTE is executed.
This command will not be executed in Stand-by mode or when the MUTE is executed.
This command will not be executed in Stand-by mode or when the MUTE is executed.
This command will not be executed in Stand-by mode or when the MUTE is executed.
This command will not be executed in Stand-by mode or when the MUTE is executed.
Status code
from the projector
Data (Receive)
Function
1
76h 50h
0
76h 50h
r1
76h 49h
r2
76h 49h
d1
76h 49h
v1
76h 49h
v2
76h 49h
0
76h 50h 4Bh
1
76h 50h 4Bh
0
76h 53h 4Dh
1
76h 53h 4Dh
ASCII
hhhhmm
HHHHxVVVV
***.**
***.**
0 (NO SIGNAL), 3 (3wire), 4 (4wire),
5 (5wire), 6 (SCART)
ASCII
****************(within 16 characters)
*******(within 7 characters)
r1 r2 d1 v1 v2
4
Note
Description
Command for setting the input signal
to COMPUTER 1
Command receipt confirmation
(Command echo back)
ASCII
Data (Receive)
31h
30h
72h 31h
72h 32h
64h 31h
76h 31h
76h 32h
30h
31h
30h
31h
Data (Receive)
Data (Receive)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fl7000uFl6900uFl7000u

Table of Contents