1. Fix the pillar support (Fig.1 Page 7) shortening or lengthening the support according to the
dimensions A and B shown in the table on page 4. The support should be fixed at a height where the gate
has a sufficiently rigid surface to fix the gate support , bearing in mind that the gate support will be fixed
15 mm lower than the pillar support. (Fig.1 Page 5).
2. Shorten or lengthen the gate support according to the dimensions for C shown in the table on page 5.
Connect the gate opener to the gate support, with the rod completely extended (Fig.2 Page 7) and with
the swivel joint nut fully tightened (Fig.3 Page 7). Once this has been done use a spirit level (Fig.4
Page 7) to mark the position of the gate support on the gate. Dismantle the gate support and fix it to the
gate using the markings previously made.
3. Mount the motor and unscrew the swivel joint nut three turns to ensure closure. Attach the security
ring and the safety bolt supplied.(Fig.6 Page 7).
4.Electrical connections: Unscrew the end cover and connect
the terminals according to the following diagram:
5. Open the door manually to the desired open position, slide the collar stopper along the arm (Fig.9
Page 7) up to the front cover plate, fixing its position with the Allen key. The hydraulic transmission can
then be plugged in and started. Re-position the collar stopper to the desired position if the angle of
opening is not the desired one.
6. Once the motor is working correctly the limit valves can be adjusted (Fig.10 Page 7). The limit valves
control the force and are independent in opening (blue limit valve) and closing (red limit valve) the gate.
The screws can be adjusted by turning them a maximum of 45º,and should be adjusted slightly above the
minimum possible, in this way the force of the hydraulic system is reduced thus increasing safety.
7. The closing buffer can then be adjusted (Fig.11 Page 7), thus avoiding the door banging closed.
To adjust the closing buffer turn the screw a maximum of 10º( If the buffer valve is completely closed
then 15mm of buffering will be lost) .
8.The aluminium arm cover can then be pressured into position (Fig.12 Page 7), followed by its plastic
cover and the end cover.
OPERATION OF THE HYRAULIC LOCK
With hydraulic powered gates it is necessary to consider the type of opening required:
- Inward opening (Fig.2, Page 5)
Kit 'KM' should be connected to
position 2 (see
diagram).
- Outward opening (Fig.3, Page 5)
Kit 'KM' should be connected to
position 1 (see diagram).
Ed1. 14/12/09 (English)
EARTH
COMMON
CONDENSER
2
1
8 of 10