Electrical - Scotsman C2648 Service Manual

Modular cuber induding prodigy plus
Hide thumbs Also See for C2648:
Table of Contents

Advertisement

C2648 Prodigy and Prodigy Plus Service Manual

Electrical

The machine is not supplied with a power cord, one
must either be field installed or the machine hard-
wired.
The dataplate on the back of the cabinet details
the power requirements, including voltage, phase,
minimum circuit ampacity and maximum fuse size.
HACR type circuit breakers may be used in place of
fuses. Extension cords are not permitted. Use of a
licensed electrician is recommended.
The ice maker is designed to operate on its own
electrical circuit and must be individually fused.
Voltage variation must not exceed the limits listed
earlier.
The remote condenser is designed to be powered
from the ice machine. A separate knockout hole has
been provided near the ice maker electrical junction
box.
Power
Supply
Electrical connections are made inside the junction
box in the back panel of the ice machine.
1. Remove the junction box cover and route the
2. Attach the remote condenser fan motor wires to
3. Install field supplied strain reliefs per code. Attach
4. Check voltage when complete.
5. Return the junction box cover to its original
Follow all applicable local, state and national codes.
Remote
Condenser
Electrical
Connection
Electrical Connections
January 2015
Page 14
power cord through the access hole and properly
attach the power supply wires to the leads in the
junction box.
the wires in the junction box tagged "fan motor
leads".
a ground wire to the ground connection in the
junction box.
position and secure with the original screws.