4. Start and stop

4-1. Start and stop engine

Start engine
IMPORTANT
1) Do not run the engine starter motor for more than 10
seconds. It may cause a breakage of the starter
motor. If the engine does not start, keep it cool for
2-5 minutes before retry. Then, execute steps (3) -
(4).
2) Never turn the main switch to start position while
engine is running.
(1) Open the fuel cock of water separator (A).
(2) Put the reverser lever and PTO shift lever to "N"
position.
(3) Set position control lever in the LOW position.
Make sure that the implement is lowered.
(4) Push accelerator lever forward to higher speed
position.
(5) Insert the key and turn it to "ON" position.
Check pilot lamps on meter panel;
(A) Battery charge pilot lamp is on.
(B) Engine oil pressure pilot lamp is on.
(6) Turn the key switch to "START" position.
(7) As engine starts, immediately release key switch and it
goes back to "ON" position automatically.
When engine starts, battery charge and engine
pressure pilot lamps turn off.
(8) Warm up the engine by running without load at 1500
rpm for about 5 minutes. Especially if the temperature
is below 0°C, at least 10 minutes warm-up is required.
(A) Water separator
(B) Fuel cock
(A) Reverser lever
(C) PTO shift lever
(A) Position control lever
(A) Accelerator lever
34
(O) Open
EF393T OM